S
YSTEM
I
NSTALLATION
Dekolink™—IDEN Repeater Hardware Manual
23
Note: Dekolink recommends to set limit (-3dB) from the output power selected.
2. Choose the
External Alarm
option to be enabled when normally Open or Close
status according to your application.
3. Press the
Door Alarm Switch
to switch the led from red to green.
4. After setting the repeater parameters, click the
Send Parameters
button.
Note: Now the repeater is loaded with the new configuration.
6.5. System Activation
1. Connect Donor and Service antennas with RF coaxial jumper to Repeater’s
“Base Port” and “Mobile Port” respectively.
2. Enable downlink and uplink amplifiers by clicking “PAmp” checkbox.
3. Click the
Send Parameters
button.
4. Check the status of the leds in the repeater alarm tab (all leds should be colored
green except the “Door open”).
5. Switch to Parameters and Control tab and check if all the parameters are as
desired.
6. Test the performance of the system in the coverage area (drive test)
7. Disconnect the data cable from the repeater and close the door with the supplied
key.
Note: The repeater is up and running….