 Section IV – Warranty and Service 

 

WARRANTY 

Deklin Technologies, Inc. warrants this product to be free from defect in workmanship and material for a 
period of 24 months from the time of installation or 26 months from the factory shipping date. This 
warranty is valid only if the equipment is installed in an aircraft by a FAA certified avionics facility (or 
other ICAO agency). 
 
If during the warranty period this unit should fail it will be at the discretion of Deklin Technologies, Inc to 
send a replacement unit or repair the original unit. All units must be returned to the factory for repair or 
replacement. 
 
All shipping and handling charges for the return of a unit to the factory are the responsibility of the 
purchaser. Domestic UPS Ground shipping charges for sending an exchange or repaired unit to the 
customer will be the responsibility of Deklin Technologies, Inc. Any additional charges as a result of 
requested improved delivery time, alternate carrier, insurance, or handling costs are the responsibility of 
the customer. All freight, handling, insurance, brokerage fees, duties and taxes for shipments outside the 
continental United States is the responsibility of the customer. 
 
Deklin Technologies, Inc shall not be liable for incidental or consequential damages. This warranty does 
not cover a defect that has resulted from improper handling, storage or preservation, unreasonable use, or 
maintenance. This warranty is void if there is any attempt to dissemble this product without factory 
authorization. This warranty does not cover expenses incurred for the removal and/or installation of this 
product.  
 
All items repaired or replaced under this warranty are warranted for the remainder of the original 
warranty period. Deklin Technologies, Inc reserves the rights to make modifications or improvements to 
the product without obligation to perform like modifications or improvements to previously manufactured 
products.  
 

FACTORY SERVICE 

In the event any unit needs to be returned to the factory, contact Deklin Technologies, Inc for a Return 
Authorization Number prior to returning. 
 
Units that arrive without a Return Authorization Number, or telephone number, will be returned un-
repaired. Deklin Technologies, Inc is not responsible for items returned via Mail. 
 

 

Deklin Technologies, Inc. 

2011 

Summary of Contents for AIU-900A

Page 1: ...AIU 900 Autopilot Interface Unit Installation Manual Rev 1 11 July 15 2012 Deklin Technologies Inc 413 Childe Harolds Lane Brentwood TN 37027 Tel 615 819 0800 Fax 615 819 0801 www deklintech com ...

Page 2: ...REVISIONS REV DESCRIPTION DATE APPROVAL 1 0 Initial Release March 5 2011 JAD 1 1 Certification requirements parts list update schematic dwg update April 15 2011 JAD 1 11 Address Change July 15 2012 JAD ...

Page 3: ...____________________________________ 2 Installation Requirements___________________________________________ 2 Unpacking and Inspection __________________________________________ 2 INSTALLATION PROCEDURES ___________________________________________ 2 Cooling Requirements _____________________________________________ 2 Mounting Requirements ____________________________________________ 2 Cable Harnes...

Page 4: ...raph a 11 ELECTRICAL PARTS AND INSTRUMENTS a Electronic Kits Kits assembled by noncertificated individuals are not eligible for installation on TC d aircraft until the part is certified as airworthy and found eligible for installation in accordance with parts 21 and 43 During and after assembly these kits should receive documented conformity inspections by properly certificated persons to ensure t...

Page 5: ...r 100V Inductor Choke 18 mH 27mH Resistors 10 0 kOhm 100 0 kOhm 0 25W 1 Trim Pots 5 kOhm 200 kOhm Single Turn Side Adj Transformers SP 66 x3 Component List AIU 900B Capacitors 0 027uF 0 047uF Metalized Polyester 100V Inductor Choke 18 mH 27mH Resistors 1 0 kOhm 100 0 kOhm 0 25W 1 Trim Pots 5 kOhm 200 kOhm Single Turn Side Adj Transformers SP 66 SP67 x2 EQUIPMENT SUPPLIED 1 each AIU 900 EQUIPMENT R...

Page 6: ...ternal shipping damage contact Deklin Technologies Inc for a replacement Do not attempt to install a damaged unit Equipment returned to Deklin Technologies Inc for any other reason should be shipped in the original packaging or other UPS approved packaging INSTALLATION PROCEDURES Cooling Requirements Forced air cooling is not required for the AIU 900 However the equipment should be kept away from ...

Page 7: ...high voltage power lines Do not bundle any lines from this unit with 400 Hz synchro wiring or AC power lines such as strobes or inverters Do not position this unit or route wiring from this unit next to any device with a strong alternating magnetic field such as an inverter Use shielded wire where shown and ground as indicated Post Installation Check After installation wiring is complete verify no...

Page 8: ...ling insurance brokerage fees duties and taxes for shipments outside the continental United States is the responsibility of the customer Deklin Technologies Inc shall not be liable for incidental or consequential damages This warranty does not cover a defect that has resulted from improper handling storage or preservation unreasonable use or maintenance This warranty is void if there is any attemp...

Page 9: ...Appendix A Schematic Deklin Technologies Inc 2011 5 ...

Page 10: ...Appendix B Interconnects Deklin Technologies Inc 2011 6 ...

Page 11: ... Deklin Technologies Inc 2011 7 ...

Page 12: ... Deklin Technologies Inc 2011 8 ...

Page 13: ... Deklin Technologies Inc 2011 9 ...

Page 14: ... Deklin Technologies Inc 2011 10 ...

Page 15: ... Deklin Technologies Inc 2011 11 ...

Page 16: ... Deklin Technologies Inc 2011 12 ...

Page 17: ... Deklin Technologies Inc 2011 13 ...

Page 18: ... Deklin Technologies Inc 2011 14 ...

Page 19: ... Deklin Technologies Inc 2011 15 ...

Page 20: ...Appendix C Mechanical Deklin Technologies Inc 2011 16 ...

Reviews: