ASSEMBLY INSTRUCTIONS MLD CONTROL EK-S1
Page 20
9 Technical Data
9.1
Electrical ratings
Nominal input voltage
100 to 240VAC/ 110-250VDC
Line frequency
50 to 60 Hz
Inrush current
30 A @ Tu 25
0
C
Input power
179W @ Uin= 230 VAC
Nominal current
0,78 A
Output voltage motors
24 VDC
Nominal output current
3A (in Manual Control mode)
Peak output current
3,1 A for 25 min / 5 A for 10 min / 14 A for 100 ms
Output voltage sensors
24 VDC
Peak output current
1,2 A (200 mA sensors, 1,0 A for wind guard heating)
Output voltage CAN-Bus
5 VDC (galvanicallyisolated)
Peak output current
0,3 A
Max. voltage for UPS potential-free contact
24 VDC
Max. current for UPS potential-free contact
0,1 A
IP protection class
IP 66 according to EN 60529, UL50 / UL746C, UL 94
Safety
EN 60950-1
Electromagnetic Interference (EMI)
EN 55032, EN 61000
Climatic conditions
Installation above sea level
max. 2000m
Operating ambient temperature
-20 °C to +50 °C
with wind guard heating
-20 °C to +20 °C
Relative humidity
5% - 95%, non-condensing
Expanded air humidity range wind guard
0% to 100%
Dimensions
245 mm x 180 mm x 111 mm
Total weight including MLD sensor
Approx. 3 kg