3 Installation  

The manufacturer accepts no liability for 
installation. Any action that the manufacturer 
has to take as a result of an erroneous 
installation will not be covered by the 
warranty. Installation, including gas and 
electrical connections, must be carried out 
by qualified personnel. An installation by an 
unqualified person may constitute a hazard. 
 
The manufacturer shall not be held 
responsible for injury to persons or  
damages arising from procedures carried out 
by unauthorized persons or due to non 
compliance with these provisions. 

 

Installation, preparation of location 
and electrical and gas installation 
for the appliance falls under the 
customer’s responsibility. 

DANGER 

The appliance must be 

installed in accordance with all 
local gas and/or electrical 
regulations. 

DANGER

 Prior to installation, 

visually check if the appliance has 
any defects on it. If so, do not 
have it installed. Damaged 
appliances are a safety risk. 

 

Before installation 

This appliance is designed for installation in 
a domestic worktop. A safety distance must 
be left between the appliance and the 
kitchen walls and furniture. See figure 
overleaf (values in mm). 

x

This appliance can also be used in a free 
standing position. Allow a minimum 
distance of 750 mm above the hob 
surface. 

x

(*) If a cooker hood is to be installed 
above the appliance, refer to the cooker 
hood manufacturers instructions regarding 
installation height (min 650 mm) 

x

Remove packaging materials and 
transport locks. 

x

Surfaces, synthetic laminates and 
adhesives used must be heat resistant 
(100 °C minimum). 

x

The worktop must be aligned and fixed 
horizontally. 

x

Cut the aperture for the hob in the 
worktop as per installation dimensions. 

 
This appliance uses LPG (Liquid petroleum 
or bottle gas) This appliance requires an 
operating pressure of 2.8-3.0 kPa. A suitable 
LPG regulator that complies with the 
requirements of SANS 1237 must be used. 
The manufacturer and  the seller do not 
accept responsibility for any damage due to 
incorrect installation or gas connection. 

  

x

Gas bottles should be located outdoors in 
a suitable ventilated lock-up. 

x

The connecting hose should not exceed 
200 cm in length. 

x

An appliance without a flame failure 
device may only be used with a free 
standing cylinder placed adjacent to but 
not closer than 300 mm to the appliance. 

Safety installation 

x

A removable horizontal board must be 
fitted below the hob and 75mm away from 
the worktop  bottom face.  

x

Space between this board and the 
appliance must be empty and no objects 
may be stored or kept there. 

x

This board will effectively shield the user 
from the base of the hob which gets hot 
during use. The board needs to be 
removable for service purposes as the 
hob, once installed, can only be loosened 
from below.  

x

If the appliance is installed with a side 
adjacent to a vertical kitchen cabinet, the 
distance between the edge of the 
appliance and that of the cabinet side 
must be a least 150mm. The distance 
between the back wall and the rear edge 
of the hob must be at least 55mm.  

Minimum of 50 mm 

Summary of Contents for DHG905

Page 1: ...Page 1 DHG905 5 BURNER GAS HOB ON GLASS Cooking Instruction manual Part number 071909...

Page 2: ...n on how to operate and care for your appliance to gain the maximum benefit from it We trust you will enjoy years of trouble free use EXPLANATION OF SYMBOLS Throughout this User Manual the following s...

Page 3: ...formation for the installer 10 Important information for the user 11 Electrical connection 12 Gas connection 12 Leakage control 13 Final check 14 Gas conversion 14 Package information 15 Future transp...

Page 4: ...ations in this manual are subject to change without notice Figures in this manual are schematic and may not match your appliance exactly Important Read these instructions for use carefully so as to fa...

Page 5: ...470 mm Burners Rear left Rapid burner Power 2900 W Front left Auxiliary burner Power 2000 W Front right Normal burner Power 1000 W Rear right Normal burner Power 2000 W Middle Wok Burner Power 3300 W...

Page 6: ...using alcoholic drinks in your dishes Alcohol evaporates at high temperatures and may cause a fire since it can ignite when it comes into contact with hot surfaces x Do not use the appliance for heati...

Page 7: ...itchen is well ventilated keep natural ventilation holes open or install a mechanical ventilation device mechanical extractor hood Prolonged intensive use of the appliance may call for additional vent...

Page 8: ...Commercial use will void the warrantee CAUTION This appliance is for cooking purposes only It must not be used for other purposes This appliance should not be used for warming plates under the grill d...

Page 9: ...650 mm x Remove packaging materials and transport locks x Surfaces synthetic laminates and adhesives used must be heat resistant 100 C minimum x The worktop must be aligned and fixed horizontally x Cu...

Page 10: ...tant information for the installer This appliance may only be installed by a registered LP Gas installer registered with the LPGSASA Liquefied Petroleum Gas Association of Southern Africa The applianc...

Page 11: ...ch complies with SANS 1237 must be used Permanent installation Important information for the user This appliance may only be installed by a registered LP Gas installer All registered installers are is...

Page 12: ...ting any work on the gas installation please shut off the gas supply x Gas adjustment conditions and values are stated on labels or on type label Your appliance is adjusted for LP gas Connecting the g...

Page 13: ...ld x If there is a leak bubbles will appear x If this happens close the valve on the gas bottle x Check and tighten the connections immediately x Repeat the procedure to ensure that there are no furth...

Page 14: ...e flow rate adjustment screw For LP Butane Propane turn the screw clockwise For natural gas you should turn the screw counter clockwise once The normal length of a straight flame in the reduced positi...

Page 15: ...general appearance of your appliance for any damages that might have occurred during transportation Disposing of the old product Dispose of the old appliance in an environmentally friendly manner Refe...

Page 16: ...rrect pot size for your dishes Larger pots require more energy Initial use First cleaning of the appliance The surface may get damaged by some detergents or cleaning materials Do not use aggressive de...

Page 17: ...ace plastic and aluminum vessels on it x Such vessels should not be used to keep foods in either x Use flat bottomed saucepans or cooking vessels only x Put only the appropriate amount of food in sauc...

Page 18: ...f the gas valves Gas valves must be controlled from 90 to 210 or 160 according to the gas valve model If flame is set from 0 to 90 the burner will be below the minimum output and may result in a flash...

Page 19: ...down before you clean it Sugar based foods such as thick cream and syrup must be cleaned promptly without waiting the surface to cool down Otherwise glass ceramic surface may be damaged permanently G...

Page 20: ...d remove the pot stands burner caps and burner bodies 1 Insert the socket into the central tube of the burner so that it locates over the brass gas jet at the bottom of the tube 2 Gently loosen the br...

Page 21: ...The lighting procedure has not been followed correctly Follow the correct lighting procedure The flame is yellow Pots and pans are stained The burners are dirty or wet Clean dry the burner components...

Page 22: ...vice defy co za Sub Saharan Africa Branches ZAMBIA SOUTHGATE INVESTMENTS LTD Plot 1606 Sheki Sheki Road P O Box 33681 Lusaka 10101 Zambia Tel 260 0211 242332 3 Fax 260 0211 242933 sgiservicecentre mic...

Page 23: ...and attention in the use and maintenance of the appliance Abuse misuse in conflict with operating instructions connection to incorrect voltages and subjection to commercial use shall release the Comp...

Page 24: ...uct at www defy co za Installer s details to be recorded below INSTALLER S NAME AND COMPANY INSTALLER S REGISTRATION NUMBER HAVE YOU RECEIVED A WRITTEN COMPLETION CERTIFICATE HAS THE INSTALLER EXPLAIN...

Reviews: