Introduction
You and your Defy stove are going to make a great team together.
But first, it will pay if you really get to know each other.
So sit down have a cup of tea and carefully read though this leaflet as well as the oper-
ating manual supplied with the product.
Unpacking
Please ensure that packaging material is disposed of in a responsible manner.
Plastic bags should be cut up to prevent children playing with them and accidentally
suffocating.
If the appliance is damaged in any way, do not use it. Report the damage to your
dealer, who will take the necessary corrective action.
Electrical installation
Model DGS 154
Electrical current is required for the flame ignition systems
as well as for operating the oven.
The power cord must be fitted with a 15 Amp 3 pin plug.
See sketch.
Insert the plug into an earthed 15 Amp wall socket.
This appliance must be earthed. The manufacturer and
the seller do not accept responsibility for any damage
due to incorrect installation or electrical connection.
Model DGS 156
Electrical current is required for the flame ignition systems as well as for operating
the oven and electric hot plates.
The connection to the power supply must be carried out by a licensed electrician,
who will ensure that the oven is correctly connected and safely earthed. The rated cur-
rent is printed on the serial number label attached to the oven door
The appliance must be connected to the mains through a double pole isolating switch
which has a minimum clearance between the contacts of 3 mm. in both poles.
A means for disconnection must be provided in the fixed wiring.
This appliance should not be connected through an earth leakage system.
Refer to S.A.B.S. 0142.
This appliance must be earthed. The manufacturer and the seller do not accept
responsibility for any damage due to incorrect installation or electrical connec-
tion.
NEUTRAL
YELLOW / GREEN
BLUE
LIVE
BROWN
EARTH
BACK OF PLUG