background image

Page 5 

Preparing for installation 

The  chimney  hood  has  the  ability  to 
either  recirculate  the  filtered  air  back 
into  the  kitchen,  or  the  filtered  air  can 
be  circulated  through  a  duct  to  the 
outside  of  the  building  or  into  the 
ceiling.   

Decide  on  which  option  best  suits  you 
before commencing with the installation. 

• 

The  chimney  hood  is  intended  to  be 
mounted  onto  a  flat  perpendicular 
kitchen  wall  capable  of  supporting  the 
weight  of  the  hood.  (approx.  16  to  26 
kg depending on the model). 

Tools required for installation: 

• 

An electric drill. 

• 

 A  3.5 mm diam. steel drill bit. 

• 

8 mm & 5 mm diam. masonry drill bits 

• 

A star screw driver (Posi 2). 

• 

A  ratchet  with  a  10  mm  socket  and  a 
100 mm extension. 

• 

A  tape  measure,  masking  tape  and  a 
pencil. 

Venting air to the outside

 

When discharging the air into a ventilation 
duct  or  directly  through  the  wall  into  the 
open, please take note of the following: 

• 

Exhaust  air  from  the  chimney  hood 
must  not  be  directed  into  a  flue  or 
chimney which is used for exhausting 
the  fumes  or  smoke  from  other 
appliances burning gas or fuels. 

• 

Please 

ensure 

that 

regulations 

concerning  the  discharge  of  exhaust 
air  have  been  fulfilled.  (SABS  IEC 
60335-2-31). 

 
For optimum chiney hood efficiency use a 
short, smooth, round air exhaust pipe with 
as  few  bends  as  possible.  A  150  mm 
diameter  exhaust  pipe  is  recommended. 
Long box section, narrowed or bent pipes 
will  hinder  performance  and  increase 
noise levels. 

• 

Connecting a 150 mm diameter pipe: 

Mount  the  pipe  directly  onto  the  air 
outlet on the extractor hood. 

• 

Connecting  a  125  mm  or  100  mm 
diameter  pipe: 

Attach  a  reducing 

connector  (available  from  a    specialist 
retailer)  to  the  air  pipe  and  then  attach 
to the exhaust-air duct.  

Care must be taken during installation not 
to obstruct these vents. 
No  ducting  is  required  for  this  type  of 
installation.

 

 

The  chimney  hood  filters  out  solid 
particles before the air is recirculated, via 
the  vents  on  the  side  of  the  upper 
chimney, into the kitchen.

 

Recirculating filtered air 

Recirculate

filtered air

 

Exhaust air through a dedicted pipe 

not shared with another fuel burning appliance.

ceiling

 

 

ceiling

ceiling

ITEM 

DESCRIPTION 

QTY 

Wall plug & screw  8 mm plug, 6 mm screw 

Wall plug & screw  5 mm plug, 5 mm screw 

Screw 

Self tapping 

10 

Washer 

Slotted 

Summary of Contents for 600 PREMIUM DCH300

Page 1: ... the space below the listed information for future reference SERIAL NUMBER DATE OF PURCHASE PURCHASED FROM 600 PREMIUM CHIMNEY HOOD DCH300 IN STAINLESS STEEL DCH301 IN BLACK 750 PREMIUM CHIMNEY HOOD DCH302 IN STAINLESS STEEL 900 PREMIUM CHIMNEY HOOD DCH306 IN STAINLESS STEEL DCH307 IN BLACK ...

Page 2: ...ION OF SYMBOLS Important information Warning Hazardous situations Warning Electric shock SAVE THESE INSTRUCTIONS Index 3 Important safety instructions 4 Description 4 Before use 4 Safety advice 4 Electrical connection 5 Preparing for installation 5 Recirculating filtered air 5 Venting air to the outside 6 Installation 7 Mounting diagram 8 Before and after use 8 Grease filters 8 Optional carbon pad...

Page 3: ...ectric shock Never use the chimney hood when your judgment or coordination is impaired by the use of alcohol and or drugs The chimney hood must be disconnected from the mains during installation maintenance cleaning and repair procedures Important safety instructions Do not place any flammable materials close to the chimney hood Make sure that the chimney hood function knobs are switched off after...

Page 4: ... damage due to incorrect electrical connection This chimney hood may not be used with a battery inverter power supply Safety advice Before use This chimney hood complies with all relevant safety regulations Never operate the chimney hood without a grease filter Never leave cooking fat or oil unattended Overheated fat or oil can easily catch fire Do not flambé food directly under the chimney hood T...

Page 5: ...ppliances burning gas or fuels Please ensure that regulations concerning the discharge of exhaust air have been fulfilled SABS IEC 60335 2 31 For optimum chiney hood efficiency use a short smooth round air exhaust pipe with as few bends as possible A 150 mm diameter exhaust pipe is recommended Long box section narrowed or bent pipes will hinder performance and increase noise levels Connecting a 15...

Page 6: ... diameter holes ensuring that they are flush with the wall Partially screw two 6 mm diameter screws into the two top wall plugs leaving them to protrude about 10 mm Lift and hook the extractor hood over and onto the two protruding screws through the key hole slots provided at the top of the extractor hood frame Insert the other two 6 mm diameter screws through the holes inside the extractor hood h...

Page 7: ...uct Drill two 3 5mm Diameter holes and secure two chimney ducts to mounting bracket Bottom chimney duct Mounting bracket Mounting Diagram INSERT 6 SELF TAPPING SCREWS 650 mm above a built in electric hob or 700 mm when installed above a built in gas hob 650 or 700 ...

Page 8: ...aturated depends on the way in which the appliance is used To prevent potential fire hazards the anti grease filters should be washed a minimum of every 2 months it is possible to use the dishwasher for this task After a few washes the colour of the filters may change This does not mean they have to be replaced If the replacement and washing instructions are not followed the anti grease filters ma...

Page 9: ...e glass cover and replace the retaining ring Switch on the electricity supply Select the fan speed you require Push button 3 for high extraction level Push button 2 for medium Push button 1 for low The fan indicator light will glow when the fan is operating To switch the fan off push the motor speed OFF button 0 If required you may illuminate the cooking area by switching the hood lights on Leave ...

Page 10: ...ree soft cloth or synthetic sponge Soap or mild liquid detergent A mild window cleaner Diluted ammonia in warm water A nylon bristle brush Cleaners labelled Suitable for stainless steel Do not use A steam cleaner Acid alcohol soda chloride or spirit based cleaners Coarse abrasive cleaning powders Metallic scourers steel wool metal scrapers or plastic scouring pads Wire brushes or emery paper So ca...

Page 11: ...details BLOEMFONTEIN 160 Long Street Hilton Bloemfontein 9301 Tel 051 400 3900 Bloemfontein Service defy co za CAPE TOWN 5A Marconi Rd Montague Gardens 7441 Tel 021 551 8314 CapeTown Service defy co za DURBAN 35 Intersite Avenue Umgeni Business Park Durban 4051 Tel 031 268 3300 Durban Service defy co za EAST LONDON 16 Bowls Rd Arcadia East London 5201 Tel 043 743 7100 EastLondon Service defy co za...

Page 12: ...dition of these warranties that the purchaser takes due care and attention in the use and maintenance of the appliance Abuse misuse in conflict with operating instructions connection to incorrect voltages and subjection to commercial use shall release the Company from its obligations 3 This warranty shall become void and cease to operate if the appliance is dismantled by or any repairs to the appl...

Reviews: