Defro Home AQUAPELL Operating Manual Download Page 6

6

 

 

 

It is absolutely forbidden to use the flammable liquid

for equipment firing up. 

 

If the substrate, on which the equipment is located, is
made of inflammable materials, such as parquet or

floor lining then you should place a protective plate un-

der it (the plate should protrude 250-300 mm from the 

front of the equipment). 

2.2.

 

WARNINGS RELATED TO OPERATION 

 

 

Equipment should be shutdown in case of failure or in-
correct operation. 

 

Fuel used in the equipment should meet the conditions

described in this manual.  

 

Internal parts of the equipment should not be washed
with water. 

 

Avoid contact with water; above all do not wash any
painted surfaces until they are fully cured. The coating 

on new devices is not an anti-corrosion coating; heat-

resistant paint achieves its protective properties only

after curing under the influence of heat (after several

ignitions). 

 

Do not expose the body to the action of hot air for a

long period of time. Do not heat excessively the room

where you are staying and where the equipment is in-

stalled. It may have an adverse impact on physical 

condition and be a reason for health problems. 

 

Equipment should be installed in rooms with fire pro-
tection and equipped with all required components

such as supply (with air) and flue gas discharge. 

 

Equipment and cladding made of ceramics should be
stored in rooms free from moisture and they cannot be

exposed to adverse effects of the weather. 

 

It is not recommended to place the body of the equip-

ment directly on the floor and if such floor is made of

inflammable materials it should be properly insulated. 

 

To facilitate possible interventions by the technical
personnel you should not place the equipment inside

the closed rooms and just by the walls what can also

disturb air intake. 

 

Always make sure and check whether doors of the
combustion chamber are tightly closed when the

equipment is operating. 

 

Equipment consumes exact amount of air which is re-

quired for combustion process; it is recommended to

connect the equipment for air intake from outside us-

ing suitable pipe and through a special outlet located

at the back of the equipment. 

ADDITIONAL INFORMATION 

 

 

In case of any problems, you should contact the sales 
outlet or qualified personnel authorized by DEFRO.

Request original spare parts if the repair is necessary.

 

Use only fuel with properties compatible with the rec-
ommendations of this operating manual. 

 

Check and clean flue gas discharge ducts (a connect-

ing piece to flue) periodically. 

 

Store this manual carefully because it should be avail-
able for a whole period of equipment operation. In

case of sale of giving the equipment to the other user,

you should always make sure whether the product has

the manual enclosed. 

 

Request a new copy from an authorized sales outlet in
DEFRO company if it has been lost. 

3.

 

INTENDED USE 

Dry stoves MYPELL are intended for combustion of pellet. They 

are intended for heating of houses and spaces where they are installed. 

They can be also used as an additional source of thermal power.  

A dry stove can be connected multiple times. 

 

DEFRO HOME AQUAPELL pellet stove with water sys-

tem can be operated only after connection to the central 

heating system and filling it with water. Only then 

proper heat discharge is ensured. Operation of the 

equipment without water and outside the CO system re-
sults in loss of warranty.  

4.

 

TECHNICAL SPECIFICATION 

4.1.

 

DESIGN 

DEFRO HOME AQUAPELL dry stove is fired with pellet and may 

be used as a source of hot water for the central heating system. Part 

of hot air is emitted directly from the furnace through the window panel 

and by radiation through convection holes over the doors and in top 

wall of the device More than 80% of heat energy is given back to water 

in water system of the stove. 

Stove body - walls in contact with fire - is made of heat-resistant 

steel sheet. Combustion chamber is encased with water system, which 

removes considerable amount of heat and transfers it to water located 

inside. Stove is equipped with so-called combustion chamber.  

 

Picture 1

.

 Design of dry stove MYPELL. 

Explanatory notes to picture 1:

 

1 – control panel with display, 2 – pellet container cover, 3 – doors, 4 – glass 
sheet, 5 – lock, 6 – STB temperature limiter, 7 – 230 V supply socket, 8 – supply 
switch, 9 – air intake socket 

Φ

 48 mm, 10 – flue 

Φ

 80 mm, 11 – socket 

Φ

1” for 

return of water from central heating system, 12 – water system of heat ex-
changer, 13 – container for pellet, 14 – pellet feeder, 15 – pellet discharge pipe, 
16 – burner, 17 – igniter, 18 – ash-pan, 19  – socket 

Φ

 1” for supply of central 

heating system, 20 - diaphragm vessel, 21 – flue gas fan, 22 – stove body, 23 

– forced-draught fan. 

Furnace chamber is equipped with discharge pellet (16) burner 

adapted for combustion of biomass. Fuel required for combustion pro-

cess is transported using automatic feeder (14), which takes the pellet 

2

1

3
4
5

11

9

10

7
8

6

17

16
23

18

13

12

20

19

21
22

15

14

Summary of Contents for AQUAPELL

Page 1: ...operating manual dry stove with water system fired with pellet DEFRO HOME AQUAPELL 13 kW translation of original operating manual issue 4 July 2020...

Page 2: ...i by przekazana wraz z piecem kominkowym w przypadku odst pienia w asno ci innej osobie This Declaration of Conformity becomes invalid if any changes have been made to the Dry Stove if its constructio...

Page 3: ...of the Warranty Card to the following address DEFRO Sp z o o Sp k Centrum Serwi sowe Ruda Strawczy ska 103a 26 067 Strawczyn fax 41 303 91 31 serwis defro pl By sending back your Warranty Card you wil...

Page 4: ...2 7 CLEANING AND MAINTENANCE 12 7 1 1 Water system 12 7 2 Basic operations and cleaning by the user 12 7 2 1 Cleaning before each starting 12 7 2 2 Every day service 13 7 2 3 Every week service 13 7 2...

Page 5: ...in this way 2 BASIC SAFETY RULES 2 1 SAFETY WARNINGS The national and local provisions should be met Equipment should be installed in compliance with the legal standards applicable in the given locati...

Page 6: ...perties compatible with the rec ommendations of this operating manual Check and clean flue gas discharge ducts a connect ing piece to flue periodically Store this manual carefully because it should be...

Page 7: ...er are given in brackets 2 Device weight depends on the selected design version and its equipment 3 The stove is factory adapted for combustion of pellet with a diameter of 6 mm pellet with a diameter...

Page 8: ...and if they are in good technical condition 5 2 WORKING ENVIRONMENT Dry stove should be installed in compliance with the re quirements of thecurrentlyapplicablestandards and le gal regulations and de...

Page 9: ...hermore the air intake should be directly connected with the room where the stove is to be installed protected with grille metal net or suitable cover not restrict ing minimum cross section located in...

Page 10: ...automated which allows automatic stoppage of operation if the safe temperature of water is exceeded Dry stove is ready for operation in closed system because it is equipped with diaphragm vessel insta...

Page 11: ...ith water should be carried our using installed fixtures for filling and emptying which should be located in the lowest point of the heating system This process should be carried out slowly in order t...

Page 12: ...hich will disconnect supply from the stove and will prevent damage of the stove and central heating system 7 CLEANING AND MAINTENANCE All operations related to cleaning of all components should be car...

Page 13: ...moval of dust from heat exchanger chamber if ash has been accumulated in the chamber it should be removed 7 2 4 EVERY MONTH SERVICE If the stove is used extensively then you should remove the soot fro...

Page 14: ...d 8 TROUBLESHOOTING Some anomalies indicating irregularities in operation can occur during operation of the equipment It can be caused by incorrect instal lation of the equipment without observation o...

Page 15: ...er subject of agreement dry stove under the condition that the product has been fully paid Due to suitable proven and unified standards of sales the war ranty covers only product purchased in authoriz...

Page 16: ...free of charge The guarantor can charge the costs connected with warranty claim only incase when claim is not accepted as a result of statingcircumstances which are listedin points 17 and 18 men tione...

Page 17: ...equipment operation by the service within 60 days from date of carrying out the repair DEFRO will issue appropriate invoice for replace ment repair of the subject component with enclosed expertise pro...

Page 18: ...18...

Page 19: ...vered as complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation manual with this Warranty Card...

Page 20: ...20 14 CARRIED OUT WARRANTY REPAIRS AND MAINTENANCE No date fault description repaired element description of repairs comments Stamp and signature of Service 1 2 3 4 5 6 7 8 9 10...

Page 21: ...vered as complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation manual with this Warranty Card...

Page 22: ...22...

Page 23: ...nician Way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date Justness of complaint Duration of repair Fault defect has been removed the equ...

Page 24: ...24...

Page 25: ...nician Way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date Justness of complaint Duration of repair Fault defect has been removed the equ...

Page 26: ...26...

Page 27: ...nician Way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date Justness of complaint Duration of repair Fault defect has been removed the equ...

Page 28: ...28...

Page 29: ...29 19 REGISTER OF INSPECTIONS OF SMOKE DUCTS date stamp and signature of chimneysweep date stamp and signature of chimneysweep...

Page 30: ...specification CO emission in combustion products 0 0098 0 0081 1 13 O2 122 mg m3 101 mg m3 1 13 O2 PN EN 14785 2009 OGC emission in combustion products 2 mg m3 4 mg m3 1 13 O2 Commission Regulation EU...

Page 31: ...zy ska 103A PARAMETERS OF THE EQUIPMENT UNIT MODEL IDENTIFICATION MYPELL Energy efficiency class Direct thermal power kW 2 9 Indirect thermal power kW 10 2 Energy Efficiency Index EEI 134 Efficiency a...

Page 32: ...509 702 720 509 577 900 DEFRO Sp ka z ograniczon odpowiedzialno ci Sp ka komandytowa 00 403 Warszawa ul Solec 24 253 Manufacturing plant Ruda Strawczy ska 103 A 26 067 Strawczyn tel 41 303 80 85 biuro...