6
It is absolutely forbidden to use the flammable liquid
for equipment firing up.
If the substrate, on which the equipment is located, is
made of inflammable materials, such as parquet or
floor lining then you should place a protective plate un-
der it (the plate should protrude 250-300 mm from the
front of the equipment).
2.2.
WARNINGS RELATED TO OPERATION
Equipment should be shutdown in case of failure or in-
correct operation.
Fuel used in the equipment should meet the conditions
described in this manual.
Internal parts of the equipment should not be washed
with water.
Avoid contact with water; above all do not wash any
painted surfaces until they are fully cured. The coating
on new devices is not an anti-corrosion coating; heat-
resistant paint achieves its protective properties only
after curing under the influence of heat (after several
ignitions).
Do not expose the body to the action of hot air for a
long period of time. Do not heat excessively the room
where you are staying and where the equipment is in-
stalled. It may have an adverse impact on physical
condition and be a reason for health problems.
Equipment should be installed in rooms with fire pro-
tection and equipped with all required components
such as supply (with air) and flue gas discharge.
Equipment and cladding made of ceramics should be
stored in rooms free from moisture and they cannot be
exposed to adverse effects of the weather.
It is not recommended to place the body of the equip-
ment directly on the floor and if such floor is made of
inflammable materials it should be properly insulated.
To facilitate possible interventions by the technical
personnel you should not place the equipment inside
the closed rooms and just by the walls what can also
disturb air intake.
Always make sure and check whether doors of the
combustion chamber are tightly closed when the
equipment is operating.
Equipment consumes exact amount of air which is re-
quired for combustion process; it is recommended to
connect the equipment for air intake from outside us-
ing suitable pipe and through a special outlet located
at the back of the equipment.
ADDITIONAL INFORMATION
In case of any problems, you should contact the sales
outlet or qualified personnel authorized by DEFRO.
Request original spare parts if the repair is necessary.
Use only fuel with properties compatible with the rec-
ommendations of this operating manual.
Check and clean flue gas discharge ducts (a connect-
ing piece to flue) periodically.
Store this manual carefully because it should be avail-
able for a whole period of equipment operation. In
case of sale of giving the equipment to the other user,
you should always make sure whether the product has
the manual enclosed.
Request a new copy from an authorized sales outlet in
DEFRO company if it has been lost.
3.
INTENDED USE
Dry stoves MYPELL are intended for combustion of pellet. They
are intended for heating of houses and spaces where they are installed.
They can be also used as an additional source of thermal power.
A dry stove can be connected multiple times.
DEFRO HOME AQUAPELL pellet stove with water sys-
tem can be operated only after connection to the central
heating system and filling it with water. Only then
proper heat discharge is ensured. Operation of the
equipment without water and outside the CO system re-
sults in loss of warranty.
4.
TECHNICAL SPECIFICATION
4.1.
DESIGN
DEFRO HOME AQUAPELL dry stove is fired with pellet and may
be used as a source of hot water for the central heating system. Part
of hot air is emitted directly from the furnace through the window panel
and by radiation through convection holes over the doors and in top
wall of the device More than 80% of heat energy is given back to water
in water system of the stove.
Stove body - walls in contact with fire - is made of heat-resistant
steel sheet. Combustion chamber is encased with water system, which
removes considerable amount of heat and transfers it to water located
inside. Stove is equipped with so-called combustion chamber.
Picture 1
.
Design of dry stove MYPELL.
Explanatory notes to picture 1:
1 – control panel with display, 2 – pellet container cover, 3 – doors, 4 – glass
sheet, 5 – lock, 6 – STB temperature limiter, 7 – 230 V supply socket, 8 – supply
switch, 9 – air intake socket
Φ
48 mm, 10 – flue
Φ
80 mm, 11 – socket
Φ
1” for
return of water from central heating system, 12 – water system of heat ex-
changer, 13 – container for pellet, 14 – pellet feeder, 15 – pellet discharge pipe,
16 – burner, 17 – igniter, 18 – ash-pan, 19 – socket
Φ
1” for supply of central
heating system, 20 - diaphragm vessel, 21 – flue gas fan, 22 – stove body, 23
– forced-draught fan.
Furnace chamber is equipped with discharge pellet (16) burner
adapted for combustion of biomass. Fuel required for combustion pro-
cess is transported using automatic feeder (14), which takes the pellet
2
1
3
4
5
11
9
10
7
8
6
17
16
23
18
13
12
20
19
21
22
15
14