background image

31

 

 

 

Summary of Contents for AIRPELL 8

Page 1: ...operating manual dry stove for pellets DEFRO HOME AIRPELL 8 translation of original operating manual issue 3 June 2020 ...

Page 2: ...kazana wraz z piecem ko minkowym w przypadku odstąpienia własności innej osobie This Declaration of Conformity becomes invalid if any changes have been made to the DEFRO HOME AIRPELL Dry Stove if its construction has been changed without our permission or if the dry stove is used not in accordance with the operating manual This Declaration shall be handed over to a new owner along with the title o...

Page 3: ...f the Warranty Card to the following address DEFRO Sp z o o Sp k Centrum Serwi sowe Ruda Strawczyńska 103a 26 067 Strawczyn fax 41 303 91 31 serwis defro pl By sending back your Warranty Card you will be registered in our DEFRO heating boilers users database and we will be able to provide you quick and professional technical support If you do not send back acorrectly filled in Warranty Card and th...

Page 4: ...fuelling 11 6 2 3 Damping 11 6 2 4 Power failure during operation 12 7 CLEANING AND MAINTENANCE 12 7 1 Basic operations and cleaning by the user 12 7 1 1 Cleaning before each starting 12 7 1 2 Every day service 12 7 1 3 Every week service 13 7 1 4 Every month service 13 7 1 5 Every year service 14 7 1 6 Window panel cleaning 14 7 1 7 Doors gaskets 14 7 1 8 Furnace chamber 14 7 1 9 Flue 14 7 2 Peri...

Page 5: ...r burns Hint Informative symbol Useful information and hints are marked in this way 2 BASIC SAFETY RULES 2 1 SAFETY WARNINGS The national and local provisions should be met Equipment should be installed in compliance with the legal standards applicable in the given location region or country The equipment should be used by apersons including children of impaired physical sensory mental capa biliti...

Page 6: ...es compatible with the rec ommendations of this operating manual Check and clean flue gas discharge ducts a connect ing piece to flue periodically Store this manual carefully because it should be avail able for a whole period of equipment operation In case of sale of giving the equipment to the other user you should always makesure whether the product has the manual enclosed Request a new copy fro...

Page 7: ... Pa 12 Flue size mm 80 Supply voltage V 230 Maximum power consumption W 583 Power consumption for nominal power1 kWh h 0 125 0 065 Fuel consumption1 kg h 1 9 0 8 Fuel tank capacity kg 16 Fuel3 the pellet with a diameter of 6 mm 1 Values for nominal power 3 5 kW are given in brackets 2 Device weight depends on the selected design version and its equipment 3 The stove is factory adapted for combusti...

Page 8: ...lity for the prod uct The dry stove is not a furnace intended for combustion of wastes and forbidden fuels cannot be combusted in it Completely emptying of the fuel tank should be avoided The minimum level of fuel container s fill 25 of its capacity DEFRO sp z o o Sp k does not accept liability for damage caused or improper burning of fuel if the fuel used is prohibited Condition of the fuel conta...

Page 9: ...ld ing designer to reinforce the floor slab or execute special structure dis tributing the weight on a larger area Flooring in the room where the dry stove is to be in stalled should be properly dimensioned to maintain the load To ensure the correct operation of dry stove you should ensure the suitable inflow of air required for combustion it is appropriate to ensure approx 40 m3 h in accordance w...

Page 10: ...pe with possible additional insulation usingproper materials thickness 1 3 5 cm heat conductivity min 0 07 W m K As an alternative is it is recommended to use insulated industrial pipe which can be also used outdoors to avoid the occurrence of conden sate For correct operation connector between the dry stove and flue or smoke duct should be executed acc to the below recommendations horizontal sect...

Page 11: ...to use the whole available thermal power This will avoid damage of ceramic tiles welds and steel structure Do not expect immediate effects of heating 6 2 FIRST START UP AND OPERATION 6 2 1 STOVE START UP Absolutely before each starting of ignition function in the controller the burner should be empty no pellet may be located inside Turn on the power supply 1 For a start up with an empty feeder fir...

Page 12: ...and maintenance works are to be carried out with meticu lous care and only by adults familiarized with this manual The drystove should not be cleaned in the presence of children Any service and maintenance works are to be carried out with meticulous care and only by adults familiarized with this manual The dry stove should not be cleaned in the presence of children 7 1 1 CLEANING BEFORE EACH START...

Page 13: ...s at least once a month Soot removal improves the flow of smoke and the quality of stove performance De scription of disassembly process for deflectors and claddings of the heat exchanger is available below The deflector is supported on two sides panels of the combustion chamber To remove it you should lift one of its sides rotate and lower it as presented on the picture and then take it out throu...

Page 14: ...cated with graphite grease Carry out inspection andclean ing of the whole stove prior to each heating season Pay special atten tion to the condition of gaskets replace them if necessary 7 1 8 FURNACE CHAMBER Clean the furnace chamber of the stove periodically depending on moisture content and type of pellet used 7 1 9 FLUE In compliancewith applicable regulations youshouldclean thefluetwo times a ...

Page 15: ...onnection with it marking in accordance with the above men tioned directive crossed bin on the waste of electronic and electric equipment is located on the rating plate Before scrapping of stove you should disconnect all components that are subject to selective collection of waste electrical and electronic equipment for disposal purposes These components include elec tronic controller feeder drive...

Page 16: ...nual filled in and stamped by an authorized point of sale or authorized distributor The fault regis tration should contain a type capacity serial number manufacturer number the in formation is located on the rating plate b date and place of purchase c brief description of the fault d detailed address and phone number of Purchaser 12 If the following cases are complained about incorrect combustion ...

Page 17: ...O Sp z o o Sp k 2 Any complaints are to be made at a sales outlet or directly at the Company on fax no 41 303 80 85 e mail serwis defro pl or by a letter to the company s address 3 Fault registration can be completed if the Purchaser has a pur chase confirmation and has filled in the Warranty Card correctly including a complaint sheet 4 The DEFRO Sp z o o Sp k 48h service does its best to re move ...

Page 18: ...18 ...

Page 19: ...vered as complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation manual with this Warranty Card filled in has been familiarised with equipment s operation and maintenance city and data user signature filled by the manufacturer filled by the user The Customer and the installation and service comp...

Page 20: ...20 13 CARRIED OUT WARRANTY REPAIRS AND MAINTENANCE No date fault description repaired element description of repairs comments Stamp and signature of Service 1 2 3 4 5 6 7 8 9 10 ...

Page 21: ...complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation manual with this Warranty Card filled in has been familiarised with equipment s operation and maintenance city and data user signature filled by the manufacturer filled by the user The Customer and the installation and service company confi...

Page 22: ...22 ...

Page 23: ... technician Way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date Justness of complaint Duration of repair Fault defect has been removed the equipment operates correctly I hereby confirm removal of the fault I declare that I have familiarised myself with conditions of war ranty on the basis of which I wish to register my complaint The Cu...

Page 24: ...24 ...

Page 25: ... technician Way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date Justness of complaint Duration of repair Fault defect has been removed the equipment operates correctly I hereby confirm removal of the fault I declare that I have familiarised myself with conditions of war ranty on the basis of which I wish to register my complaint The Cu...

Page 26: ... technician Way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date Justness of complaint Duration of repair Fault defect has been removed the equipment operates correctly I hereby confirm removal of the fault I declare that I have familiarised myself with conditions of war ranty on the basis of which I wish to register my complaint The Cu...

Page 27: ...27 17 REGISTER OF INSPECTIONS OF SMOKE DUCTS date stamp and signature of chimneysweep date stamp and signature of chimneysweep ...

Page 28: ...rmance Technical specification CO emission in combustion products 0 010 0 017 1 13 O2 115 mg m3 201 mg m3 1 13 O2 PN EN 14785 2009 OGC emission in combustion products 7 mg m3 13 mg m3 1 13 O2 Commission Regulation EU 2015 1185 NOx emission in combustion products 57 mg m3 59 mg m3 1 13 O2 Commission Regulation EU 2015 1185 PM emission in combustion products 17 mg m3 16 mg m3 1 13 O2 Commission Regu...

Page 29: ...ska 103A PARAMETERS OF THE EQUIPMENT UNIT MODEL IDENTIFICATION DEFRO HOME AIRPELL Energy efficiency class Direct thermal power kW 8 0 Indirect thermal power kW N A Energy Efficiency Index EEI 129 Efficiency at nominal thermal power 93 3 Efficiency at minimal thermal power 94 3 Special precautions during assembly instal lation or maintenance of the equipment Consider guidelines included in the Serv...

Page 30: ...30 ...

Page 31: ...31 ...

Page 32: ... 509 702 720 509 577 900 DEFRO Spółka z ograniczoną odpowiedzialnością Spółka komandytowa 00 403 Warszawa ul Solec 24 253 Zakład produkcyjny Ruda Strawczyńska 103 A 26 067 Strawczyn tel 41 303 80 85 biuro defro pl NIP 9591968493 ...