Picture 7. Example of connection of DEFRO HOME AIRPELL stove to 

flue with condensate discharge. 

5.6.

 

CONNECTION TO ELECTRIC SYSTEM 

Electrical installation of the DEFRO HOME AIRPELL dry stove is in-

tended for supply from mains with 230 V/50 Hz. Room, where the stove 

is installed, should be equipped with electrical system 230V/50Hz exe-

cuted as TN-C or TN-S systems (with the protective conductor or pro-

tective-neutral conductor) according to the regulations in force. Electric 

system (without regard for the type of installation made) should be 

ended with plug-in socket equipped with protective conductor contact. 
Plug-in socket should be located in the safe distance from the heat 

emission source. 

 

Using a socket without connected protective terminal

causes an electric shock hazard! 

All connections to the electric system can be executed

only by the electrician having suitable certifications /of

the Polish Electricians Association 1kV/. 

User is forbidden to take off covers of the electronic

controller or fan and to make any interventions or mod-

ification in electrical connections. 

6.

 

USAGE AND OPERATION 

Combustion chamber should be closed during operation of the stove. 

So, it is forbidden to open the doors when the flame is burning in the 

burner. 

6.1.

 

INTRODUCTORY REMARKS 

 

Do not touch stove during first firing-up, because the

paint is hardening during this stage. 

Touching the paint could result in uncovering of the 

steel surface. 

It is possible to refresh it using spray paint of the same colour if neces-

sary. 

 

It is good practice to ensure efficient ventilation during

first firing-up because small amounts of smoke and

paint odour will be emitted from the stove. 

Do not stay near the stove. It is required to vent the room. Smoke and 

paint odour will disappear after approx. one hour of operation. How-

ever, we remind that they are not harmful to health. 

The stove is subject to expansion and shrinkage during warming and 

cooling down stage what may cause slight squeaks. This is an abso-

lutely normal phenomenon because a structure of the equipment is 

made rolled steel and this phenomenon shall not be considered as a 

defect. 

It is very important to avoid excessive overheating of the stove at the 

beginning but to reach the required temperature gradually. Use low 

heating powers. During the next firing-up of the stove, it will be possible 

to use the whole available thermal power. This will avoid damage of 

ceramic tiles, welds and steel structure. 

 

Do not expect immediate effects of heating! 

6.2.

 

FIRST START-UP AND OPERATION 

6.2.1.

 

STOVE START-UP 

 

Absolutely, before each starting of ignition function in 

the controller the burner should be empty (no pellet 

may be located inside).

 

Turn on the power supply. 

1.

 

For a start-up with an empty feeder (first start-up or start-up when 

whole fuel from the container has been used up) you should start-

up pellet feeder (endless screw):  

a.

 

press button 

,  

b.

 

using     buttons select 

Menu Customization 

 

Manual load, 

 

c.

 

press again 

,

 a

 

d.

 

using   

buttons select 

ON 

option and confirm 

pressing . 

e.

 

Shutdown the endless screw using 

OFF 

option when 

you head pellet falling into the burner. 

2.

 

Return to the main menu with a button 

3.

 

Switch on 

Ignition

 with 

 button. Successive stages of the 

combustion cycle will be carried out automatically. 

4.

 

Please inspect the size and brightness of the flame for 15-20 

minutes during the combustion process, when the stove is in “

op-

eration

” mode. It should have a length of approx. 20-40cm during 

operation with 100% rated power - depending on the size of the 

stove (burner). 

More information concerning servicing the controller is included in the 

NG01 HYDRO controller’s operating manual.

 

 

Housing components will be very hot during operation. 

You must exercise caution. 

6.2.2.

 

REFUELLING 

Fuel should be refilled on a regular basis to ensure that is level does 

not fall below 10-25% of maximum loading. Use caution during refuel-

ling, in particular when the stove is hot. After opening cover of the con-

tainer the pellet should be added vigorously, with short breaks allowing 

proper setting of the fuel. Close the cover tightly as soon as the refuel-

ling is completed, in particular when the stove is in operation.  

Avoid contact of pellet packaging (e.g. bags) with hot components of 

the stove. Take care to avoid getting other materials than pellet into the 
container. Pieces of fuel larger than the allowable size of the pellet may 

result in jamming or damage of mechanism of the feeder.  

It is forbidden to use another type of fuel than the pellet. Fuel should 

be stored in a safe distance from the stove (minimum 2 m from the 

stove). 

6.2.3.

 

DAMPING 

Routine damping of the stove is based on the selection of the 

Damping 

function from the controller menu. The controller will lock fuel feeding 

and the stove will be damped after combustion of the current dose of 

flue with

condensate discharge

rosette

mortar

non-flammable

material

cleaning opening

SET

SET

SET

ESC

Summary of Contents for AIRPELL 8

Page 1: ...operating manual dry stove for pellets DEFRO HOME AIRPELL 8 translation of original operating manual issue 3 June 2020 ...

Page 2: ...kazana wraz z piecem ko minkowym w przypadku odstąpienia własności innej osobie This Declaration of Conformity becomes invalid if any changes have been made to the DEFRO HOME AIRPELL Dry Stove if its construction has been changed without our permission or if the dry stove is used not in accordance with the operating manual This Declaration shall be handed over to a new owner along with the title o...

Page 3: ...f the Warranty Card to the following address DEFRO Sp z o o Sp k Centrum Serwi sowe Ruda Strawczyńska 103a 26 067 Strawczyn fax 41 303 91 31 serwis defro pl By sending back your Warranty Card you will be registered in our DEFRO heating boilers users database and we will be able to provide you quick and professional technical support If you do not send back acorrectly filled in Warranty Card and th...

Page 4: ...fuelling 11 6 2 3 Damping 11 6 2 4 Power failure during operation 12 7 CLEANING AND MAINTENANCE 12 7 1 Basic operations and cleaning by the user 12 7 1 1 Cleaning before each starting 12 7 1 2 Every day service 12 7 1 3 Every week service 13 7 1 4 Every month service 13 7 1 5 Every year service 14 7 1 6 Window panel cleaning 14 7 1 7 Doors gaskets 14 7 1 8 Furnace chamber 14 7 1 9 Flue 14 7 2 Peri...

Page 5: ...r burns Hint Informative symbol Useful information and hints are marked in this way 2 BASIC SAFETY RULES 2 1 SAFETY WARNINGS The national and local provisions should be met Equipment should be installed in compliance with the legal standards applicable in the given location region or country The equipment should be used by apersons including children of impaired physical sensory mental capa biliti...

Page 6: ...es compatible with the rec ommendations of this operating manual Check and clean flue gas discharge ducts a connect ing piece to flue periodically Store this manual carefully because it should be avail able for a whole period of equipment operation In case of sale of giving the equipment to the other user you should always makesure whether the product has the manual enclosed Request a new copy fro...

Page 7: ... Pa 12 Flue size mm 80 Supply voltage V 230 Maximum power consumption W 583 Power consumption for nominal power1 kWh h 0 125 0 065 Fuel consumption1 kg h 1 9 0 8 Fuel tank capacity kg 16 Fuel3 the pellet with a diameter of 6 mm 1 Values for nominal power 3 5 kW are given in brackets 2 Device weight depends on the selected design version and its equipment 3 The stove is factory adapted for combusti...

Page 8: ...lity for the prod uct The dry stove is not a furnace intended for combustion of wastes and forbidden fuels cannot be combusted in it Completely emptying of the fuel tank should be avoided The minimum level of fuel container s fill 25 of its capacity DEFRO sp z o o Sp k does not accept liability for damage caused or improper burning of fuel if the fuel used is prohibited Condition of the fuel conta...

Page 9: ...ld ing designer to reinforce the floor slab or execute special structure dis tributing the weight on a larger area Flooring in the room where the dry stove is to be in stalled should be properly dimensioned to maintain the load To ensure the correct operation of dry stove you should ensure the suitable inflow of air required for combustion it is appropriate to ensure approx 40 m3 h in accordance w...

Page 10: ...pe with possible additional insulation usingproper materials thickness 1 3 5 cm heat conductivity min 0 07 W m K As an alternative is it is recommended to use insulated industrial pipe which can be also used outdoors to avoid the occurrence of conden sate For correct operation connector between the dry stove and flue or smoke duct should be executed acc to the below recommendations horizontal sect...

Page 11: ...to use the whole available thermal power This will avoid damage of ceramic tiles welds and steel structure Do not expect immediate effects of heating 6 2 FIRST START UP AND OPERATION 6 2 1 STOVE START UP Absolutely before each starting of ignition function in the controller the burner should be empty no pellet may be located inside Turn on the power supply 1 For a start up with an empty feeder fir...

Page 12: ...and maintenance works are to be carried out with meticu lous care and only by adults familiarized with this manual The drystove should not be cleaned in the presence of children Any service and maintenance works are to be carried out with meticulous care and only by adults familiarized with this manual The dry stove should not be cleaned in the presence of children 7 1 1 CLEANING BEFORE EACH START...

Page 13: ...s at least once a month Soot removal improves the flow of smoke and the quality of stove performance De scription of disassembly process for deflectors and claddings of the heat exchanger is available below The deflector is supported on two sides panels of the combustion chamber To remove it you should lift one of its sides rotate and lower it as presented on the picture and then take it out throu...

Page 14: ...cated with graphite grease Carry out inspection andclean ing of the whole stove prior to each heating season Pay special atten tion to the condition of gaskets replace them if necessary 7 1 8 FURNACE CHAMBER Clean the furnace chamber of the stove periodically depending on moisture content and type of pellet used 7 1 9 FLUE In compliancewith applicable regulations youshouldclean thefluetwo times a ...

Page 15: ...onnection with it marking in accordance with the above men tioned directive crossed bin on the waste of electronic and electric equipment is located on the rating plate Before scrapping of stove you should disconnect all components that are subject to selective collection of waste electrical and electronic equipment for disposal purposes These components include elec tronic controller feeder drive...

Page 16: ...nual filled in and stamped by an authorized point of sale or authorized distributor The fault regis tration should contain a type capacity serial number manufacturer number the in formation is located on the rating plate b date and place of purchase c brief description of the fault d detailed address and phone number of Purchaser 12 If the following cases are complained about incorrect combustion ...

Page 17: ...O Sp z o o Sp k 2 Any complaints are to be made at a sales outlet or directly at the Company on fax no 41 303 80 85 e mail serwis defro pl or by a letter to the company s address 3 Fault registration can be completed if the Purchaser has a pur chase confirmation and has filled in the Warranty Card correctly including a complaint sheet 4 The DEFRO Sp z o o Sp k 48h service does its best to re move ...

Page 18: ...18 ...

Page 19: ...vered as complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation manual with this Warranty Card filled in has been familiarised with equipment s operation and maintenance city and data user signature filled by the manufacturer filled by the user The Customer and the installation and service comp...

Page 20: ...20 13 CARRIED OUT WARRANTY REPAIRS AND MAINTENANCE No date fault description repaired element description of repairs comments Stamp and signature of Service 1 2 3 4 5 6 7 8 9 10 ...

Page 21: ...complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation manual with this Warranty Card filled in has been familiarised with equipment s operation and maintenance city and data user signature filled by the manufacturer filled by the user The Customer and the installation and service company confi...

Page 22: ...22 ...

Page 23: ... technician Way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date Justness of complaint Duration of repair Fault defect has been removed the equipment operates correctly I hereby confirm removal of the fault I declare that I have familiarised myself with conditions of war ranty on the basis of which I wish to register my complaint The Cu...

Page 24: ...24 ...

Page 25: ... technician Way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date Justness of complaint Duration of repair Fault defect has been removed the equipment operates correctly I hereby confirm removal of the fault I declare that I have familiarised myself with conditions of war ranty on the basis of which I wish to register my complaint The Cu...

Page 26: ... technician Way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date Justness of complaint Duration of repair Fault defect has been removed the equipment operates correctly I hereby confirm removal of the fault I declare that I have familiarised myself with conditions of war ranty on the basis of which I wish to register my complaint The Cu...

Page 27: ...27 17 REGISTER OF INSPECTIONS OF SMOKE DUCTS date stamp and signature of chimneysweep date stamp and signature of chimneysweep ...

Page 28: ...rmance Technical specification CO emission in combustion products 0 010 0 017 1 13 O2 115 mg m3 201 mg m3 1 13 O2 PN EN 14785 2009 OGC emission in combustion products 7 mg m3 13 mg m3 1 13 O2 Commission Regulation EU 2015 1185 NOx emission in combustion products 57 mg m3 59 mg m3 1 13 O2 Commission Regulation EU 2015 1185 PM emission in combustion products 17 mg m3 16 mg m3 1 13 O2 Commission Regu...

Page 29: ...ska 103A PARAMETERS OF THE EQUIPMENT UNIT MODEL IDENTIFICATION DEFRO HOME AIRPELL Energy efficiency class Direct thermal power kW 8 0 Indirect thermal power kW N A Energy Efficiency Index EEI 129 Efficiency at nominal thermal power 93 3 Efficiency at minimal thermal power 94 3 Special precautions during assembly instal lation or maintenance of the equipment Consider guidelines included in the Serv...

Page 30: ...30 ...

Page 31: ...31 ...

Page 32: ... 509 702 720 509 577 900 DEFRO Spółka z ograniczoną odpowiedzialnością Spółka komandytowa 00 403 Warszawa ul Solec 24 253 Zakład produkcyjny Ruda Strawczyńska 103 A 26 067 Strawczyn tel 41 303 80 85 biuro defro pl NIP 9591968493 ...

Reviews: