background image

NI-268  

index 1 

June 2021 

 Assembly Cable / Cable gland 

 
 
 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Unscrew the nut [B] from the cable gland [C].

 

 

Pass the connection cable inside the nut, then the cable gland to connect it to the terminal block [D].

 

 

Tighten the nut [B].

 

 

Connect the connections to the terminal block.

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

Reassembling the cover 

 

 
 
 
 
 
 
 
 
 

  Position the cover in the notch on the base. Fin in the alignment above. 

 
 
 
 
 
 
 
 
 
 

  Press the cover onto the base. 

 
 
 
 
 
 
 
 
 

 

 

Lock by turning the cover clockwise until the fins of the cover and the base are aligned.

 

 
 

  

Pneumatic connexion on VEOX   

 

 

 

  

Sorio® Basic 3EV unit

 
 
 

 

 

 
 
 
 
 
 
 
 
 
EV1:  Solenoid valve 
EV2:  Solenoid valve 
EV3:  Solenoid valve 

1

:      Main actuator air inlet 

2:      Upper valve actuator air inlet 
3:      Lower valve actuator air inlet 

E

:      Exhaust 

P

:      Air pressure 

ACT

: Exhaust or air intake 

 

 
 

 

 

 Apply pressure to the channel [P]. 

  Connect channel [1] of the main actuator to channel 

[1] of the unit. 

  Connect the channel [2] of the upper valve actuator to 

the channel [2] of the unit. 

  Connect channel [3] of the unit to channel [ACT] of 

the unit for the bottom valve actuator. 

  Put a pierced plug on the channel [E] of the unit. 

EV2

 

EV1

 

EV3 

ACT 

Cover fin 

Cover fin 

Cover fin 

Base fin 

Pierced 

plug 

ACT 

Sensor 

High Position

 

Sensor 

Low Position

 

Terminal 

block 3EV 