NI-268
index 1
June 2021
Assembly Cable / Cable gland
•
Unscrew the nut [B] from the cable gland [C].
•
Pass the connection cable inside the nut, then the cable gland to connect it to the terminal block [D].
•
Tighten the nut [B].
•
Connect the connections to the terminal block.
Reassembling the cover
•
Position the cover in the notch on the base. Fin in the alignment above.
•
Press the cover onto the base.
•
Lock by turning the cover clockwise until the fins of the cover and the base are aligned.
Pneumatic connexion on VEOX
Sorio® Basic 3EV unit
EV1: Solenoid valve
EV2: Solenoid valve
EV3: Solenoid valve
1
: Main actuator air inlet
2: Upper valve actuator air inlet
3: Lower valve actuator air inlet
E
: Exhaust
P
: Air pressure
ACT
: Exhaust or air intake
•
Apply pressure to the channel [P].
•
Connect channel [1] of the main actuator to channel
[1] of the unit.
•
Connect the channel [2] of the upper valve actuator to
the channel [2] of the unit.
•
Connect channel [3] of the unit to channel [ACT] of
the unit for the bottom valve actuator.
•
Put a pierced plug on the channel [E] of the unit.
EV2
EV1
3
2
EV3
P
ACT
E
1
B
D
Cover fin
Cover fin
Cover fin
Base fin
3
P
Pierced
plug
2
ACT
1
C
Sensor
High Position
Sensor
Low Position
Terminal
block 3EV
D
B