10
Operation
1
Adjusting the lamp head
□
If needed, gently grasp the lamp head (A) and
tilt it up or down or side to side to adjust the
light coverage area.
W
2
Determining the motion sensor
detection zone
NOTE:
When the control dial is set to the “TEST” position,
the light will operate during the day or night. The light will
stay on for 5 seconds after all motion is stopped.
NOTE:
The motion sensor will need to completely warm
up (up to 30 seconds) before beginning the setup process.
□
Turn the control dial (D) to the TEST position.
□
Turn the sensitivity dial (E) to the “L” position.
□
Perform a “walk test”: walk in an arc across
the front of the motion sensor (C).
□
Watch the light (B). The light (B) will come on
indicating motion has been detected.
□
Stop, wait for the light (B) to turn off, and then
begin walking again.
□
Continue this process until the detection zone
has been established.
W
L
H
M
W
OFF
60S
TEST
3
Adjusting the sensitivity
□
If needed during the “walk test”, turn the
sensitivity dial (E) to the desired sensitivity
(“L”, “M”, “H”).
NOTE:
The motion sensor is more sensitive to motion
moving across the front of the sensor. The motion sensor is
less sensitive to motion moving directly toward the sensor.
NOTE:
The higher the sensitivity setting, the greater the
possibility of false triggering. To reduce false triggering,
turn the sensitivity dial to the “L” or “M” position.
W
L
H
M
A
D
E
B
B
C
E