14. DESCRIPTION OF AUDIBLE AND VISUAL SIGNALS
Condition
LCD Readout
LEDs
Horn
CO detector is
operational
Displays
continuously
POWER
green LED flashes
once every 60 seconds
Silent
CO gas alarm
Displays current CO
reading in PPM
ALARM
red LED flashes 4
times in synchronous with
horn
Beeps 4 times, pauses for
5 seconds. Repeats this
pattern for first 5 minutes.
Then pause time increases
to 60 seconds.
Mute CO alarm
audible signal
Displays
for 5
seconds
ALARM
red LED flashes 4
times
Silent
CO gas alarm in
Silent mode
Displays current CO level
in PPM
POWER
green LED flashes
once every 60 seconds
Silent for 5 minutes
Testing detector
Displays current CO level
detected
ALARM
signals are same
as CO gas alarm condition,
and
POWER
green LED
blinks once when testing
complete
Beeps 4 times, pauses for
5 seconds, then beeps 4
times again
Display CO Level
Displays current and
highest CO levels
detected, and duration of
peak CO level. Each
readout lasts 5 seconds
POWER
green LED blinks
once when CO level display
readout is completed
Silent
Clear Peak
Memory
Displays
POWER
green LED blinks
once when clear peak
memory is completed
Bursts a long beep
Low battery
voltage
Displays
symbol
POWER
green LED blinks
for 5 seconds every minute
Chirps once per minute
Mute “low battery
voltage” audible
signal
Displays
for 5
seconds
POWER
green LED blinks
for 5 seconds
Silent
Low battery in
Silent mode
Displays
symbol
POWER
green LED blinks
for 5 seconds every minute
Silent for 24 hrs during the
first week
“End-of-Life”
Displays
continuously
SERVICE
red LED glows for
3 seconds every minute
Chirps once per minute
Mute “End-of-Life”
audible signal
Displays
for 5
seconds
SERVICE
red LED glows for
5 seconds, then Green LED
blinks once
Silent
“End-of-Life” in
Silent mode
Displays
continuously
SERVICE
red LED glows for
3 seconds every minute
Silent for 60 hrs during the
first month
Service required
Displays
continuously
SERVICE
red LED blinks for
5 seconds every minute
Chirps twice (BEEP-BEEP)
per minute