AHD DVR User Manual
30
Picture 4.22
Interval:
Only one alarm signal is turned on even there are several motion detection signals in this interval.
Alarm Out:
Start the external equipment of corresponding linkage alarm when the motion detection alarm is turned
on.
Delay:
Delay a few moments to stop when the alarm state is turned off. The range is 10~300 seconds.
Record channel:
Choose the recording channel (multiple options supportive). Trigger the recording signal when the
alarm is turned on.
Note
:
Set in the “Main Menu”
“Record”
“Record Plan” and perform the linkage recording. And set
“Desktop Shortcut Menu”
“Record Mode” to be configured, motion detection linkage recording can work.
Tour:
Choose the recording channel (multiple options supportive), which will tour preview with single screen when
the alarm is turned on.
PTZ Activation:
Click Set button to set the PTZ linkage when the alarm is turned on.
Picture 4.23
Note: Using PTZ linkage needs to set preset, cruise between points and scan etc (“Desktop Shortcut Menu”
“PTZ Control”
“Set”).
Record delay:
After stopping alarm, it is the extended period to stop alarm recording, the range is 10~300 seconds.
Show Message:
means popping the alarm information dialog box in the local host computer’s screen.
Send Email:
means sending an email to user when the alarm is turned on.