background image

SeaLite

®

 

Lumos

Operator’s Manual

11

Appendix C

Low-Voltage DC Step Response Curve

Summary of Contents for SeaLite Lumos 1000

Page 1: ...late Serial Pin out Postive Pin Negative Pin Ground Pin Dimming if applicable Pin DEEPSEA POWER LIGHT Operator s Manual T 858 576 1261 F 858 576 0219 4033 Ruffin Road San Diego CA 92123 1817 USA www deepsea com sales deepsea com Original Instruction REV 07 01 15 SeaLite Lumos ...

Page 2: ...ot 32º Electrical Specifications Lumos 2000 Lumos 1000 Input Voltage 10 36V DC 90 270V AC 50 60Hz 100 350V DC Current 1 10A 24V DC 2 65A 10V DC 0 27A 120V AC 0 13A 240V AC Power 26 5W max 32 0W max Dimming 0 5V DC AC phase control TRIAC variable voltage VARIAC Dimensions 1 87 47 5 1 69 42 9 2 47 62 6 2 40 60 9 1 59 40 3 59 15 6 08 154 3 7 35 186 7 1 85 47 1 00 25 4 1 00 25 4 4X 1 4 20 UNC OR 4X M6...

Page 3: ...Symbols 4 General Notes and Warnings 4 Pre Dive Inspection 4 Post Dive Inspection 4 5 Troubleshooting 5 Flooded Light Repair 5 Limited Warranty 5 RMA Procedure for Repair 5 Appendix A Dimming Response Curve 6 Appendix B Driver Efficiency 9 Appendix C LVDC Step Response Curve 11 Appendix D Beam Patterns 14 ...

Page 4: ...ir the body may reach temperatures in excess of 65 C These temperatures may be enough to cause burns if the light is handled without protective clothing Do not operate any high voltage electrical equipment in or around water without using a Ground Fault Interrupt circuit GFI and an isolation transformer especially when divers are in the water WARNING Do not clean any part of the light head with an...

Page 5: ... outside of the box All shipments should be sent to the address below DeepSea Power Light Attn RMA 4033 Ruffin Road San Diego CA 92123 1817 U S A Tel 858 576 1261 Fax 858 576 0219 e mail RMA deepsea com Limited Warranty Seller warrants that the goods except internal electronic components sold under this contract will be free from defect in material and workmanship for a period of one year from the...

Page 6: ...SeaLite Lumos Operator s Manual 6 Appendix A Dimming Response Curves ...

Page 7: ...put Input Phase Angle SeaLite Lumos 1000 Phase Cut Dimming Response SLL 1000 120VAC 60Hz SLL 1000 240VAC 50Hz 0 20 40 60 80 100 0V 20V 40V 60V 80V 100V 120V 140V 160V Output Input RMS Voltage SeaLite Lumos 1000 Variable Voltage Dimming Response SLL 1000 120VAC 60Hz SLL 1000 High Voltage DC ...

Page 8: ...SeaLite Lumos Operator s Manual 8 0 20 40 60 80 100 0 0V 1 0V 2 0V 3 0V 4 0V 5 0V 6 0V Output Dimming Input Voltage SeaLite Lumos 2000 Analog Dimming Response ...

Page 9: ...SeaLite Lumos Operator s Manual 9 Appendix B Driver Efficiency ...

Page 10: ...V 310V 360V Efficiency Input RMS Voltage SeaLite Lumos 1000 Efficiency SLL 1000 VAC 60Hz SLL 1000 VAC 50Hz SLL 1000 DC 0 0 5 1 1 5 2 2 5 3 3 5 0 20 40 60 80 100 6V 12V 18V 24V 30V 36V Current A Efficiency Input DC Voltage SeaLite Lumos 2000 Efficiency Efficiency Input Current ...

Page 11: ...SeaLite Lumos Operator s Manual 11 Appendix C Low Voltage DC Step Response Curve ...

Page 12: ...SeaLite Lumos Operator s Manual 12 0 10 20 30 40 50 60 70 80 90 100 0V 1V 2V 3V 4V 5V 10 0 10 20 30 40 50 Output Control Pulse V Time ms SLL 2000 DIM Input Step Response Characteristics Trigger Output ...

Page 13: ...SeaLite Lumos Operator s Manual 13 DIM Input Pulse Response Rise Time SLL 2000 LVDC DIM Input Pulse Response Fall Time SLL 2000 LVDC ...

Page 14: ...SeaLite Lumos Operator s Manual 14 Appendix D Beam Patterns ...

Page 15: ...550 SeaLite Lumos Spot SLL 1000 DW S PV SeaLite Lumos Flood SLL 2000 DW F A05 2607 0 1000 2000 3000 4000 5000 6000 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Radial Lux Intensity Comparison 90 0 80 0 70 0 60 0 50 0 40 0 30 0 20 0 10 0 0 0 10 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 90 0 0 25 50 75 100 Degrees Output Angular Distribution ...

Reviews: