CONDITIONS IN REGARDS TO USE OF THE

 

MPULSE 3000

®

 

POOL 

WATER TREATMENT SYSTEM

 

 

Results  of  use  with  the  MPULSE  3000

®

  Pool  Water  Treatment  System  may  vary.    As 

with  any  swimming  pool  product  of  this  nature,  overall  success  depends  on  many 
factors which include but are not limited to: 
 

 

Amount  of  calcium  hardness  contained  in  the  water  (Recommended  levels  are 
200-400 PPM) 

 

Age of water (water should be changed every 3-4 years) 

 

Source of water (private well, municipality, etc.) 

 

Age and wear of the swimming pool surfaces 

 

Chemical maintenance and pH balance 

 

Seasonal  temperatures  and  duration  of  filtering  cycle  (8  hours  minimum  in 
season adjust as water requires) 

 

Porous surfaces (i.e. rock features) and splash areas around spill-ways and at pool 
water level 

 

Pool  owners  and  service  personnel  must  remember  that  regular  maintenance  and 
scheduled service must be followed in order for the MPULSE 3000

®

 to provide the highest 

level of performance.  This includes a regular weekly maintenance schedule consisting of 
(but not limited to): maintaining a pH level between 7.2 and 7.6, maintaining an Alkalinity 
level  between  80  to  120  PPM.    Maintenance  should  also  include  regularly  brushing  the 
water line, spillways, tile, and water features, as well as any other calcium plagued areas of 
the swimming pool. 

 

Generally, Muriatic Acid is used in swimming pools to lower the pH level, and to aid in 
balancing Alkalinity. 
 
Maintaining  a  pH  level  between  7.2  and  7.6  in  swimming  pool  water,  helps  to  ensure 
other pool chemicals work properly.  It also helps prevent damage to pool surfaces and 
equipment, and it also helps prevent eye irritation. 
 
While  controlling  the  form  of  calcium  in  the  swimming  pool,  the 

MPULSE  3000

® 

also 

aids  in  the  process  of  balancing  the  pH  levels  by  releasing  the  positive  hydrogen  ions 
from the calcium bicarbonate.  In high concentrations, acid can also free these positive 
ions from calcium bicarbonate. 
 

Adding  unnecessary  Muriatic  Acid  will  change  the  conductivity  of  the  water  and  could 
effect the operation of the 

MPULSE 3000

® 

 and negate the scale reduction.  

When the acid 

Summary of Contents for mPULSE3000

Page 1: ...mPULSE3000 Pool water treatment system Instruction Owner s Manual ...

Page 2: ...oltage Connection Instructions 4 Instructions for use with Salt Water Generator 5 Instructions for Voltage Manual Select Switch 6 Field Installation Instructions 7 Trouble Shooting 8 Regular Maintenance Specifications 9 10 Warranty Registration 11 877 882 4695 ...

Page 3: ...he load side of the timer only to run with the circulation pump a The length of the cable from the chamber to the Electronic Control Box CANNOT be lengthened or shortened it is a specific length to ensure that the impedance of the chamber is matched properly with the control head to maximize calcium scaling prevention b The AC power connection from the electronic control head to the timer is the r...

Page 4: ...AGE CONNECTION INSTRUCTIONS SIMPLY FIT THE FEMALE END OF THE PLUG ON THE LOW VOLTAGE CABLE THAT CONNECTS TO THE CHAMBER ONTO THE MALE END ON THE ELECTRONIC CONTROL BOX WHICH IS LOCATED ON THE UNDERSIDE OF THE BOX ...

Page 5: ...oving the three screws holding it on You will see the equivalent of the above diagram Note the switch labeled A and B Standard position is A This will be used for swimming pools with standard sanitization chlorine etc For use with a Salt Water Chlorine Generator and high conductivity pools change the switch to the B position Either position can be used to decalcify pool Unit will keep salt generat...

Page 6: ...it is 220 230V The majority of swimming pool equipment sets are provided with 220 240V electrical power If you come across a swimming pool that instead utilizes 100 120V power please use the following instructions 1 Using a flat head screwdriver place it in the slot in the Voltage Select Switch currently labeled 230V 2 Move the Voltage Select Switch to the left carefully until it reaches the far l...

Page 7: ...size UL Listed conduit fitting into 7 8 diameter opening and tighten install in accordance with the fitting s instructions Fitting and conduit should be suitable for the installation environment such as liquid tight conduit and installed in compliance with all applicable local ordinances and the NEC a The AC INPUT terminal can handle COPPER wire 8 to 18 AWG solid or stranded 3 Pull new copper wiri...

Page 8: ...amber Lack of proper water flow will lead to a Red Function light 3 Ensure that there are no shorts or opens in the Chamber cord 4 Change to alternative conductivity switch position if red LED remains illuminated 5 Have you recently treated the pool with muriatic acid or chlorine This could change the conductivity of the water leading to a red light Wait for 48 hours and check again 6 Check chemis...

Page 9: ... This includes a regular weekly maintenance schedule consisting of but not limited to maintaining a pH level between 7 2 and 7 6 maintaining an Alkalinity level between 80 to 120 PPM Maintenance should also include regularly brushing the water line spillways tile and water features as well as any other calcium plagued areas of the swimming pool Generally Muriatic Acid is used in swimming pools to ...

Page 10: ... Output Voltage 50Vpp Max Output Current 350mA RMS Output Frequency 4 1 KHz 0 1 KHz Max Temperature 140º F 60º C Weight 6 Lbs or 2 72 kg Size 9 x 5 x 4 Mechanical Torque 16 in lbs Wire Range 8 18 AWG Insulation Strip length 5 16 IMPORTANT NOTE The mPULSE3000 does not remove calcium and due to evaporative conditions calcium will still be visible in SPLASH ZONES around water features zero edge pools...

Page 11: ...e of your pool spa and or water feature along with your regular weekly chemical and maintenance service Detach Here MPULSE 3000 Pool Water Treatment System WARRANTY REGISTRATION CARD must be returned to activate Date of Purchase____________________________________________________ Serial Numbers Control Box________________Chamber ________________ Under metal plate 6 digit number attached to chamber...

Reviews: