TALTERI DIVK-C91 INSTALLATION
WALL ATTACHMENT
The wall mounting kit includes a ceiling mounting plate, a wall-mounting plate
and 15 mm thick insulation pieces
The wall-mounting plate is installed about 25 mm below the roof surface.
The wall attachment plate will be fixed to the wall and then the unit lifted up
to the attachment plate, checked into perfectly horizontal position and then drill holes
for the metal screw through the mounting plate in to the bottom of the machine.
Roof moldings can be put around the machine.
KITCHEN EXHAUST DUCT
The channel output (5) in intended for extract duct of the cooker hood.
If the extract duct of the cooker hood is not in use, it must close.
If the cooker hood is connected to the kitchen extract duct (past heat recovery),
all the basic ventilation holes of the cooker hood closing damper must be closed
and in the kitchen is needed a separate extract valve which is connected
to the extract air duct.
3
DOOR REVERSAL EXHANGE
Door reversal can be changed by pushing the hinge pin
e.g with narrow tip screwdriver from the machine below
or from above.
The air exchange unit is meant for warm inner facilities. Suitable installation spots are,
among others, office, dressing or household facilities and technical or warm storages. In case
the temperature of the installation location is lower than ro om temperature, the factory settings
of the appliance must be changed to obtain faultless functioning. The unit can not be installed
into cold outer premises or garages.
UPPER BASE DUCT
The channelling is usually mounted to the upper base thermal insulation.
The steam barrier puncture must be carefully sealed. While installing the unit to
channels, steel steam barrier plate, supplied as extra, will come handy. The steam
barrier plate is attached securely between the roof trusses, 10mm smaller hole
must be cut into the gasket mat and channels are installed through the plate.
The steam barrier must be hermetically taped.
The unit can be attached right to the steam barrier plate with four M8 thread bars
at desired height. Note the measurements of the steam barrier plate during the
installation process.
The bolts and thread bars are purchased separately.
CONDENSATE WATER
Condensate drain is connected to the machine condensate connector (3/8 "external thread).
Condensate can be made at a least 10 mm in the bore copper pipe or Relatively stiff hose.
The water pipe Making about 10 cm in the water trap and the tube is connected to a floor drain.
The water line shouldnt be connected directly to the sewer.