Cleaning
Dedrone
16
v0.4 IM-Inst-RF160en
9 Decommissioning
9.1 Shut down the RF-160
RF-160 breaks
By disconnecting the cable of the power supply without shut down the RF-160, the RF-160 could
break.
•
Always shut down the RF-160 before disconnecting the cable.
You have the possibility to shut down the RF-160 via the DroneTracker user interface or directly on
the sensor.
Shut down via DroneTracker user interface:
1
Log in to the DroneTracker UI.
2
Choose
OPTIONS
>
Site Configuration
.
3
Right-click on the desired RF-160.
4
Choose
System
>
Shutdown hardware.
Briefly press the activation button at the RF-160 in the
grip recess
.
]
The RF-160 shuts down and the blue light goes out.
Shut down directly at the RF-160:
9.2 Dismantling
9.3 Disposal
Dispose the RF-160 at the end of its service life in accordance with the disposal re-
gulations for electronic waste which apply at the installation location at that time.
Alternatively, send it back to Dedrone GmbH with shipping paid by sender, and labe-
led "ZUR ENTSORGUNG" ("FOR DISPOSAL").
8 Cleaning
Wrong cleaner damages the housing
The wrong cleaner can damage the housing or antenna of the RF-160. Never use glass cleaner or
other solvent cleaner to clean the RF-160.
•
Use solvent-free cleaner to clean the RF-160.
Hot surface due to permanent sunlight
The surface of the RF-160 may become hot from permanent strong sunlight.
•
Wear safety gloves when dismantling the device.