Page 1: ...Operating Instructions DEB1200D Electronic Ballast DLH1200D Daylight Fixture ...

Page 2: ...risk 5 E Cooling 6 F Repair and maintenance 6 G Additional precautions 7 4 Power factor correction PFC 7 5 Installing lamps 7 6 Stand fitting 8 7 Starting operation of the system 9 8 Operational elements 11 9 Adjusting light intensity 14 10 Adjusting the silent mode 14 11 Transport 15 12 Connection diagram Ballast and the light head cable 16 13 Connection diagram mains cable 16 14 Technical data S...

Page 3: ...intended exclusively for use with the Dedolight DLH1200D daylight light head The DEB1200D electronic ballast is equipped with active power factor correction The light head is to be used with a 800W daylight lamp which provides the highest possible color rendition index RA 92 and a color temperature of approximately 5600K The Dedolight DEB1200D electronic ballast offers the capability of dimming th...

Page 4: ...osition in between The adjustability of the beam has been enhanced by a super spot position The holders on the front ring of the fixture accept accessories such as the barndoor filter holder or projection attachment which are secured by a latch on the top left side of the fixture A handle on the rear side of the fixture which can be unfolded for operation or folded for transport allows for easy pa...

Page 5: ...explosive media Caution Do not put light into transport case while still hot C OUTDOOR OPERATION The DEB1200D electronic ballast and DLH1200D light head are built according to Safety Class IP23 wet location The light head cable and connectors are in accordance with IP67 and can be laid on wet ground provided correct seating of the connector lock rings is assured D UV RISK The lamp used in the ligh...

Page 6: ...air department or qualified service personnel Only manufacturers original replacement parts are to be used Mains input and output of the electronic ballast are not isolated Extreme care must be taken when taking measurements on the ballast or light head with power applied No grounded measuring instruments should be used and all relevant safety precautions must be observed The ignitor produces dang...

Page 7: ...th traditional ballasts An additional advantage is the continuos range of input voltage from 90 264 AC 5 INSTALLING LAMPS A Put red mains switch on ballast to off position O Disconnect ballast from mains B After switching off the light fixture allow the lamp to totally cool before attempt ing to change the lamp Wait at least fifteen minutes to minimize the danger of an exploding lamp Open the door...

Page 8: ...s as described in 3F After the door has been closed the black latches must engage audibly Average lifetime of the 800W metal halogen lamp is about 700 hours This refers to a cycle of three hours on and one hour off Frequent on off switching dimming or use in boost position shortens lamp life The probability of an explosion of the lamp is very low However if the average lifetime is exceeded by more...

Page 9: ... phase of a metal halogen lamp to full brightness can last up to three minutes This is indicated by blinking of the control indicator At reached working temperature of Lamp the control indicator lights up continuously Switch the lamp off by pushing red push button stop on the ballast or on the light head B Automatic mode With the mode selector switch in AUTOPOSITION the lamp will ignite by swit ch...

Page 10: ...ains switch Presence of power is indicated by light in the switch Ballast is now in ready state Set the DMX adress by pushing the yellow push buttons and simulaniously until the display stars blinking and release buttons Now select channel with or buttons The selected channel is for dimming 50 135 The next following channel is automatically selected for the ON OFF feature Auto store of channel aft...

Page 11: ...h start button DMX Mains switch Mains cable socket Push button light head off Control indicator ballast overheated DMX control unit Yellow dot shows correct DMX IN signal Channel selectors Display DMX channel Socket for DMX OUT Socket for DMX IN Fan with self adjusting speed Push button light head on Light head cable socket Control indicator light head connected light head door closed Control indi...

Page 12: ...rror Front Lens Lamp socket Carriage Open door for Lamp replacement Accessory holder Latch for accessory holder Ignitor housing Ø 5 8 16 mm stand fitting inside Locking screw Ø 1 8 28 mm stand fitting outside Stirrup bale Tilt lock lever Light head cable 8 Operational elements DLH1200D ...

Page 13: ... operating instructions DEB1200D and DLH1200D Second lock latch for door Lock latch for door Push button light head on Focusing knob Push button light head off Folding handle see page 8 B A A B 8 Operational elements DLH1200D ...

Page 14: ... 1 The metal halogen lamp is regulated to a constant power of 800W which meets lamp manufacturers recommendation Dimming 50 135 Dimming is possible with the yellow three position switch set to dimming position mode selector 1 When in dimming position the light intensity can be regulated on the left knob from 450 1200W When dimmed electronically the lamp is not in an optimum operational state Opera...

Page 15: ... chosen in order to minimize damage from strong vibration The lamp should not be removed from the light head before transport Caution Lamp must be fully seated in the lamp socket and knurled fixing screw closed Do not operate fixture without lamp or with improperly installed lamp Failure to follow these instructions may cause damage to lamp socket which is not covered under warranty ...

Page 16: ...00 3 5 7 red 0 5 mm2 grey 0 5 mm2 white 0 5 mm2 20 AWG yellow green 2 5 mm2 blue 1 5 mm2 brown 1 5 mm2 18 AWG Schaltbau 12 CONNECTION DIAGRAM BALLAST AND THE LIGHT HEAD CABLE Binder 1 2 3 4 100 240V IN Amphenol phase neutral code pin protection earth 13 CONNECTION mains cable ...

Page 17: ...0V 264V AC Over voltage cut off integrated to mains switch cut out above 265V AC Current consumption 5 0A U 240V AC 12 0A U 100V AC at maximum lamp power 1200W Mains frequency 50 cycle 60 cycle 47 65 cycle Power factor With active power factor correction stabilized to cos 0 98 Efficiency Typically 0 90 depending on lamp and mains voltage Operational temperature 5 C to 35 C 41 F to 95 F max 30 C 86...

Page 18: ...r outlet slit openings on ballast are obstructed fan failed or is obstructed by foreign object Solution Eliminate cause and reactivate ballast after cool down period E When pushing the start key and Lamp control indicator and Ready control indicator beginns blinking yellow switch equipment OFF and separate it from mains Possible causes no lamp installed lamp not seated deep enough in socket lamp d...

Page 19: ...ct wiring improper installation lightning or other incidence of excessive voltage or use in violation of instructions furnished by us nor to any equipment which may have been tampered with altered or repaired by other than Dedotec or its authorized service agencies Dedotec is not responsible or liable for indirect special or consequential dama ges arising out of or in connection with the use or pe...