GT 220A

¯ 

Alays follow the safety instruction described below or labels

ahdered to the boiler. failure to follow such instruction may result in
personal injury, including loss of life or damage to the boiler and
surronding property.
iNSTRUCTIONS & SAFETY WARNING LABELS: These
instructions and labels must never be removed or covered. Replace
damaged or illegible instructions and labels. 
The boiler casing is not designed for structual support DO NOT
STAND ON OR USE THE BOILER AS A LADDER.
IF YOU SMELL GAS OR COMBUSTION RELATED FUMES,
PROCEED AS FOLLOWS:

`

Do not smoke or generate fire or sparks

`

Do not operate any electrical devices or switches

`

Close the gas supply cock to the appliance

`

Open doors and windows

`

Warn those present to leave the building

`

Do not use any phone in the building

`

Call your local gas supplier once outside the building, if you
cannot reach them call the local fire department.

DO NOT USE THE BOILER IF ANY PORTION OF THE CONTROL
SYSTEM HAS BEEN SUBJECTED TO WATER, INGESTED WITH
WATER OR SUBMERGED IN WATER.
IMMEDIATELY CALL YOUR SERVICE COMPANY TO INSPECT
AND REPLACE ALL CONTROLS AND GAS COMPONENTS.
Boiler Modification and spare parts:
This boiler use specific original manufactured parts, the boiler must
not be modified or use non OEM parts, without the written approval
from DDR Americas Inc. De Dietrich Boilers.
Installation, servicing & maintenance of this boiler shall be
completed by a licenced and trained individual, experinced in
hot water boiler heating and gas & oil combustion. The
installation must conform to all national and local codes having
jurisdication:

`

In Canada CSA B149.1 Gas Code & CSA B139 Oil Code

`

In USA ANSI Z223.1 (NFPA 54) Gas Code, NFPA 31 Oil Code
& ASME CSD-1 Automatically fired boilers.

If you have any technical questions or need assistance with
this product, please call us toll free
1.800.943.6275 E.S.T. Monday thru Friday 08:00 - 17:00 EST

0.2 Description

S2NA control panel is designed specifically for the De Dietrich
GT120-220A series cast iron sectional boilers, they are
approved for use with the above mentioned boiler series, they
are not approved to be used with any other boiler series or
manaufacturers.
The panel is designed for to be used with a power burner

Application(s): 
Space heating only
DHW heating possible with seperate control
Single or 2 stage* burners
2 stage 
Modulating burner require a seperate control 
a single heating circuits non 

0.3 Control overview

S2NA Panel overview

1. Wiring terminal strip

Summary of Contents for ME50

Page 1: ...symbols or important items The operating manual is part of the documentation along with the boiler The installer is required to explain the heating system and boiler operating instructions to the owner Notice Please read this manual and retain for future reference Improper installation adjustment alteration service or maintenance can cause injury loss of life or property damage Refer to this manua...

Page 2: ...person or company There are no owner serviceable parts on this control the usage of Non OEM parts void any product warranty and approvals The manufacturer is not responsible nor held liable for any improper use or failure to maintain this control is good operating condition Always Observe the power polarity This control requires to be earth grounded bonded If the control must be protected from wat...

Page 3: ... Boiler Modification and spare parts This boiler use specific original manufactured parts the boiler must not be modified or use non OEM parts without the written approval from DDR Americas Inc De Dietrich Boilers Installation servicing maintenance of this boiler shall be completed by a licenced and trained individual experinced in hot water boiler heating and gas oil combustion The installation m...

Page 4: ...TB safety test button testing of fixed hi limit 9 Illuminated main On Off switch 10 AUTO O MANU pump control not part of the safety or operating limits AUTO digital control pump operation O pump off MAN basic panel pump control pump operates continously 0 4 Technical Info Power supply 120VAC 10 single phase with neutral and ground earth Maximum 10A operation fuse breaker protected Safety Hi Limit ...

Page 5: ...ll make electrical connections All wiring must comply with the latest national and local electrical codes NEC NFPA70 CSA 22 2 Main fuse disconnect must be provided 15A max Suitable strain relief and wire protection must be provided All wiring UL CSA approved type suitable for the installation and must be at least 18awg 0 75mm2 rated for 300v 90 C min The equipment must be earth grounded bonded No ...

Page 6: ... X X N L Operator Limit Circuit Gnd 1 2 3 4 4 X Burner terminals not all terminal designations shown 3 5 Open terminals Panel Internal Wiring Legend symbol Description ZG main power switch Earth Ground DJ 10A Fuse breaker TS Safety limit SPDT manual reset Panel wire terminals ZSTB switch Man Auto STB TCH1 1st stage or limit control TCH2 Aux Limit or 2nd stage Limit optional usage ZP Aux pump switc...

Page 7: ...ital Control Wiring 1st Stage 2nd stage Gnd N Only used with Optional BMS Digital Control N L Gnd 1 2 3 4 4 X Burner terminals not all terminal designations shown 5 3 7 Open terminals ATTENTION WARNING FAILURE TO FOLLOWING THIS WIRING DIAGRAM MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY INCLUDING DEATH Wiring must be in strict compliance with CSA C22 2 and NEC NFPA 70 All wiring shown supplied...

Page 8: ... This control are not pro vided and are by others MAN AUTO STB Switch Must be in the MAN position for the basic panel operation STB Testing safety fixed Hi limit AUTO Not used no function ATTENTION WARNING FAILURE TO FOLLOWING THIS WIRING DIAGRAM MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY INCLUDING DEATH Wiring must be in strict compliance with CSA C22 2 and NEC NFPA 70 All wiring shown supp...

Page 9: ...rol BURNER CONTROL POWER N L Gnd 1 2 3 4 4 X Burner terminals not all terminal designations shown 3 X X k1 X X Limit Circuit Operator 2nd stage Limit Circuit Operator Open terminals ATTENTION WARNING FAILURE TO FOLLOWING THIS WIRING DIAGRAM MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY INCLUDING DEATH Wiring must be in strict compliance with CSA C22 2 and NEC NFPA 70 All wiring shown supplied a...

Page 10: ...iring 1st Stage 2nd stage Gnd N Only used with Optional BMS Digital Control BURNER CONTROL POWER N L Gnd 1 2 3 4 4 X Burner terminals not all terminal designations shown 3 T6 T7 T8 k 1 T1 T2 Limit Circuit Operator 2nd Stage Limit Circuit 2nd stage operator Open terminals ATTENTION WARNING FAILURE TO FOLLOWING THIS WIRING DIAGRAM MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY INCLUDING DEATH Wiri...

Page 11: ...wn 3 BMS Remote x x L N N L x x x x x x All contact must be dry Operator Limit 1 stage control Operator Limit 2 stage control Heating Pump Control DHW Pump Control Open terminals N GND X X k1 X X Limit circuit Operator 2nd stage Limit circuit Operator Panel Internal Wiring Legend symbol Description ZG main power switch Earth Ground DJ 10A Fuse breaker TS Safety limit SPDT manual reset Panel wire t...

Page 12: ...12 GT 220A 06 01 09 XXXX XXXX R0 T T T T T T T T 0 1 0 0 1 0 0 13 Principle wirig diagram ...

Page 13: ...13 11 13 09 XXXX XXXX R0 GT 220A 0 1 55 56 57 58 58 59 60 61 ...

Page 14: ...14 GT 220A 06 01 09 XXXX XXXX R0 ...

Page 15: ...15 11 13 09 XXXX XXXX R0 GT 220A ...

Page 16: ...ario N3E 1A3 CANADA Tel 519 650 0420 Fax 519 650 1709 In USA or South America 1054 North DuPage Avenue Lombard Illinois USA 60148 Tel 630 953 2374 Fax 630 953 2376 Toll Free 1 800 943 6275 www dedietrichboilers com In the interest of customers DE DIETRICH DDR Americas are continuously endeavouring to make improvements in product quality All the specifications stated in this document are therefore ...

Reviews: