35
If the instructions for installation for the gas hob specify a
greater distance, this must be adhered to.
Electrical connection
The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area. If it not fitted
with a plug (direct mains connection) or if the plug is not
located in an accessible area apply a bi-polar switch in
accordance with standards which assures the complete
disconnection of the mains under conditions relating to over-
current category III, in accordance with installation
instructions.
Warning:
Before re-connecting the hood circuit to the mains
supply and checking the efficient function, always check that
the mains cable is correctly assembled.
Mounting
Fig. 5-6
Before beginning installation:
•
Check that the product purchased is of a suitable size for
the chosen installation area.
• To facilitate installation, remove the fat filters and the
other parts allowed and described here, dismantle and
mount it.
To remove see also the relative paragraphs.
•
Remove the active carbon (*) filter/s if supplied (see also
relative paragraph). This/these is/are to be mounted only
if you want lo use the hood in the filtering version.
• Check (for transport reasons) that there is no other
supplied material inside the hood (e.g. packets with
screws (*), guarantees (*), etc.), eventually removing
them and keeping them.
•
If possible, disconnect and move freestanding or slide-in
range from cabinet opening to provide easier access to
rear wall/ceiling. Otherwise put a thick, protective
covering over countertop, cooktop or range to protect
from damage and debris. Select a flat surface for
assembling the unit. Cover that surface with a protective
covering and place all canopy hood parts and hardware
in it.
• Disconnect the hood during electrical connection, by
turning the home mains switch off.
•
In addition check whether near the installation area of the
hood (in the area accessible also with the hood mounted)
an electric socket is available and it is possible to
connect a fumes discharge device to the outside (only
suction version).
• Carry out all the masonry work necessary (e.g.
installation of an electric socket and/or a hole for the
passage of the discharge tube).
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood.
Do not tile, grout or silicone this
appliance to the wall. Surface mounting only.
An aesthetic flue can be purchased as an optional accessory.
Check with the assistance centre whether the model in your
possession envisages this possibility.
We advise installing the hood after having purchased the flue
to check with certainty the most suitable installation.
•
Trace a central line on the wall in order to ease mounting
(
1
), position the hole template in a way that the middle
line printed on top corresponds to the central line marked
previously and the lower side of the mask corresponds to
the lower part of the hood once mounted.
(2).
• Make 3 holes Ø 8 mm with a drill and fix the support
bracket with two dowels and screws to the wall
(3),
insert
the third dowel into the lower hole.
•
Only for chimney installation:
Apply the support
bracket
„G“
to the adherent ceiling, use the chimney
support bracket as a hole scheme (if present, the small
eyelet found on the support should coincide with the line
previously traced on the wall) and trace with a pencil 2
holes, drill the holes (Ø8mm), insert 2 plugs.
Fasten the support bracket to the wall with 2 5x45mm
screws
(4)
.
• Open the vapour scheme and remove the grease filters
(see relevant paragraph).
• Hang the hood
(5)
, regulate the position
(6-7)
and fasten
it securely with one screw and washer
(8)
.
• Carry out electrical connections
(9)
, but leave the hood
disconnected from the general electrical main panel.
• Install the flange supplied on the exit hole of the hood
(10a)
.
•
Carry out the connection of one tube (
11
– tube and ties
for fastening not included, they need to be bought) for the
fume discharge to the connection ring placed on top of
the extractor motor unit.
The other end of the tube should be connected to a fume
expulsion device towards the outside, in case the hood is
used in extractor version.
•
Fix the upper cover with 3 screws.
(12)
Note:
this is supplied already mounted in some cases.
•
Only for chimney installation:
In case you want to use
the hood in filtering version, fasten the deflector
F
to the
support bracket, and connect the other side of the tube to
the connection ring placed on the deflector
(13)
.
Apply the chimneys and fasten them on with two screws
(
14a
) to the chimney support bracket
„G“
(
14b
). and
make the lower part of the chimney slide into the suited
part on top of the chimney.
• Mount the grease filters and close the vapour scheme.
Warning!
If the hood has to be used in extractor version,
remove, if supplied, the carbon filter and the fastening
wand (placed on the back of the grease filters – see
relative paragraph).
If the hood has to be used in filtering version, make sure
that the carbon filter is already mounted on the back of
the grease filter, or in case it’s missing, buy it and install
it.
Note – only for installation without chimneys:
In case
you want to use the hood in filtering version, install the
grille/deflector instead of the flange
(10b)
.