4. Select Holiday.
5. Enter the start and end dates and times for the absence period.
6. Indicate the temperature required throughout the absence period.
Important
For a domestic hot water zone, the setpoint temperature during an
absence period is set automatically to the DHW reduced setpoint
parameter.
7. Select Confirm to confirm the setting.
5.9
Monitoring the energy consumption
If the installation is equipped with an energy meter, the energy
consumption can be monitored.
1. Press the key.
2. Select
. User settings
3. Select Energy counter.
Tab.24
Parameter
Description
CH Energy Consumed
AC005
Energy consumed for central heating
Cool Energy consumed
AC007
Energy consumed for cooling
The energy consumed since the last energy consumption meter
reset is displayed.
5.10 Starting and stopping the heat pump
5.10.1 Starting the heat pump
1. Switch on the outdoor unit and the indoor unit.
The heat pump will begin an automatic vent programme (which lasts
approx. three minutes), run each time the power is switched on. If
there is a problem, an error message is displayed on the home
screen.
2. If an error message is displayed on the home screen, contact the
installer.
3. Check the hydraulic pressure in the installation indicated on the user
interface.
Important
Recommended hydraulic pressure between 1.5 and 2.0 bar.
Fig.59
MW-6000875-1
Fig.60
MW-6000865-02
Fig.61
MW-6000890-1
5 Operation
7748711 - v03 - 08062020
AWHP MIV-S
31