9
24/06/2011 - 300020522-001-F
AD252
3
Pairing a remote control
The pairing must be done in the boiler room on first
initialisation.
Each radio remote control is given a unique identifying number in the
factory, which enables the radio module to recognise it. This
identifying number is transmitted to the radio module by the pairing
sequence described below.
This operation is memorised, even after the batteries are
changed.
Press the button on the radio module using the tip of a ballpoint
pen. The light on the radio module comes on.
The radio module exits the pairing programme after 2 minutes.
Press simultaneously for 5 sec. on keys
2
%
and
on the
remote control.
The text
cir A
is displayed.
Turn the settings button to select the desired circuit.
Press the settings button to confirm the selection.
After a few seconds, the light on the radio module goes off
and the remote control displays the message "init" while it
sychronises itself with the module.
After a few seconds, the message is cleared and the current display
appears.
Pairing failed
If there is a problem, the warning light goes out after 2 minutes
and the remote control displays the message
Pb rF
.
If the message
Pb rF
appears, the radio module is not paired with
the radio remote control. Repeat the pairing sequence.
1
2
3
C002352-C
C002353-C
MODE
%
0
2
4
6
8
10
12
14
16
18
22
24
20
$
4
5
C002354-E
6
7
C002355-E
1
2