10. Confirm the selection by pressing the
key.
11. Repeat steps 8 to 11 to define the comfort periods to and
the associated status to .
Important
No setting: 10 minutes
The setting
determines the end.
12. Go back to the main display by pressing the
h
key.
Example:
Times
06:00-22:00
06:00
22:00
06:00-08:00
11:30-13:30
06:00
08:00
11:30
13:30
06:00-08:00
11:30-14:00
17:30-22:00
06:00
08:00
11:30
14:00
17:30
22:00
6.4
Reading out measured values
The measured values are available in the Information menu of the
different PCBs.
Certain parameters are displayed:
according to certain system configurations,
according to the options, circuits or sensors actually connected.
Tab.28 Choosing the menu
Counters
Selection
Measured values on circuit A
Choose the EHC–04 menu
Measured values on circuit B
Choose the SCB-04 menu
Measured values connected to the
operation of the heat pump
Choose the EHC–04 menu
Values measured connected to the
operation of the boiler
Choose the CU-OH–04 menu
Tab.29 Values available (X) in the sub-menus EHC–04, SCB-04
Parameter
Description
Unit
EHC–04
CU-OH–04
SCB-04
AM002
"Silent mode" status
X
AM010
The current pump speed
%
X
X
AM012
Current main status of the appliance.
See
Control system sequence chapter
X
X
X
AM014
Current sub status of the appliance.
See
Control system sequence chapter
X
X
X
AM015
Is the pump running?
X
X
AM016
Flow temperature of appliance.
°C
X
X
AM019
Water pressure of the primary circuit.
bar
X
X
AM027
Instantaneous outside temperature
°C
X
X
X
AM040
Temperature used for hot water control
algorithms.
°C
X
X
AM056
Wate flow rate in the system
l/min
X
6 Settings
7613346 - v06 - 02072019
200 ESL HYBRID
43