Domestic Hot Water menu - User Level
Tab.17 Domestic Hot Water menu (
)
Parameters
Description
Factory setting
AUTOMATIC
Domestic hot water production is determined by the setting in the #TIME
PROGRAM menu.
COMFORT 7/7
Domestic hot water production is forced at all times: seven days a week.
Current time + 1
hour
COMFORT ->
Domestic hot water production is forced until the set time:
Current time + 1
hour
#MEASURES menu - User Level
Certain parameters are displayed:
according to certain system configurations,
according to the options, circuits or sensors actually connected.
Tab.18 Menu #MEASURES
Parameters
Description
Unit
OUTSIDE TEMP.
Outside temperature
°C
ROOMTEMP.A
Room temperature on circuit A
°C
ROOMTEMP.B
Room temperature on circuit B
°C
ROOMTEMP.C
Room temperature on circuit C
°C
BOILER TEMP.
Water temperature in the boiler
°C
PRESSURE
Water pressure in the system
°C
OIL PRESSURE
Oil circuit pressure
bar (MPa)
DHW TEMP.
Water temperature in the domestic hot water tank
°C
STO.TANK.T.AUX
Water temperature in the second domestic hot water tank connected to the Aux
iliary circuit
°C
S.TAN.T.AUX.BO
Water temperature in the bottom of the domestic hot water tank
°C
S.TAN.T.AUX.BO
Water temperature in the bottom of the second domestic hot water tank connec
ted to the Auxiliary circuit
°C
TEMPERATURE DCW
Domestic cold water temperature
°C
SWIMMING P.T.B
Water temperature of the swimming pool on circuit B
°C
SWIMMING P.T.C
Water temperature of the swimming pool on circuit C
°C
OUTLET TEMP.B
Water flow temperature in circuit B
°C
OUTLET TEMP.C
Water flow temperature in circuit C
°C
TEMP.SYSTEM
Water flow temperature in the system if multi-generator
°C
T.DHW BOTTOM
Water temperature in the bottom of the domestic hot water tank
°C
TEMP.TANK AUX
Water temperature in the second domestic hot water tank connected to the Aux
iliary circuit
°C
TEMP.DHW A
Water temperature in the domestic hot water tank connected to circuit A
°C
DHW B TEMP.
Water temperature in the domestic hot water tank connected to circuit B
°C
DHW TEMP.C
Water temperature in the domestic hot water tank connected to circuit C
°C
TEMP.EXCHANGE
Temperature measurement on the heat exchanger sensor
°C
BACK TEMP
Temperature of the boiler return water
°C
FAN SPEED
Fan rotation speed
rpm
POWER
Instantaneous output relative to the boiler:
0%: burner off or operating at minimum output
100%: operating at maximum output
%
HEAT CONS.
Energy consumed by the boiler in heating mode
kWh
DHW CONS.
Energy consumed by the boiler in domestic hot water mode
CURRENT
Ionisation current
µA
6 Settings
34
200 ASL HYBRID
7613348 - v06 - 10122018