Product name
200 ASL
Hybrid 8MR-2
+ AGC 25
200 ASL
Hybrid 11MR-2
+ AGC 25
200 ASL
Hybrid 16MR-2
+ AGC 25
Heating water operating limit temperature
WTOL
°C
80
80
80
Electrical power consumption
Off mode
P
OFF
kW
0.009
0.009
0.009
Thermostat-off mode
P
TO
kW
0.049
0.049
0.049
Stand-by
P
SB
kW
0.022
0.028
0.028
Crankcase heater mode
P
CK
kW
0.055
0.055
0.055
Supplementary heater
Rated heat output
(1)
Psup
kW
5.8
9.0
13.7
Type of energy input
Gas
Gas
Gas
Other specifications
Capacity control
Variable
Variable
Variable
Sound power level, indoors - outdoors
L
WA
dB
48 – 66
47 – 69
47 – 69
Annual energy consumption under average
conditions
Q
HE
kWh
GJ
5859
8
7869
13
11525
20
Annual energy consumption under colder con
ditions
Q
HE
kWh
GJ
6548
6
8009
8
10810
10
Annual energy consumption under warmer
conditions
Q
HE
kWh
GJ
1904
0
2580
0
4120
0
Rated air flow rate, outdoors for air-to-water
heat pumps
—
m
3
/h
3300
6000
6000
Declared load profile
L
L
L
Daily electricity consumption
Q
elec
kWh
4.816
4.816
4.816
Annual electricity consumption
AEC
kWh
968
968
968
Water heating energy efficiency
ƞ
wh
%
106.00
106.00
106.00
Daily fuel consumption
Q
fuel
kWh
0.000
0.000
0.000
Annual fuel consumption
AFC
GJ
0
0
0
(1) The rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater
Psup is equal to the supplementary capacity for heating su(Tj).
(2) If
Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
See
The back cover for contact details.
3.2.5
Circulating pump
Important
The benchmark for the most efficient circulating pumps is EEI ≤
0.20.
The circulating pump in the indoor module is a variable speed pump. It
adapts its speed to the distribution network.
3 Technical specifications
7613348 - v06 - 10122018
200 ASL HYBRID
23