background image

Dedicated Micros ©2008

MSU

Technical Specification

PART NUMBER

 

MSUA1T25   

MSUA2T5   

MSUA3T75   

MSUA5T0 

STORAGE  

(UNFORMATTED)

   1.25TB 

 

2.5TB 

 

3.75TB 

 

5.0TB 

 

FORMAT

 

5 x 250GB HDD 

5 x 500GB HDD 

5 x 750GB HDD 

5 x 1.0TB HDD

DVR INTERFACE 

SATA

ENVIRONMENTAL 

CONTROL

 

Intelligent individual disk cooling

POwER SUPPLy

 

1 x 200W Internal

HEALTH  

MONITORING

 

Continuous (Disk and Cooling fans)

MAINTENANCE

 

Field maintainable HDD and fans with front panel access

AC INPUT  

VOLTAGE 

120v (60HZ) / 240v (50HZ): Selectable

OPERATING  

TEMPERATURE

 

5°C-45°C

OPERATING  

HUMIDITy

 

5%-85% Non-Condensing

CONFIGURATION

 

2U Rack Mount

DIMENSION (MM)

 

89mm (H) x 440mm (W) x 537mm (D)

wEIGHT

 

16.65kg

Summary of Contents for MSUA1T25

Page 1: ...MSU Managed Storage Unit Setup and Maintenance Guide ...

Page 2: ... these manuals are accurate and current Dedicated Micros reserve the right to alter or modify the specification of the machine described herein without prejudice Contents Dedicated Micros MSU Managed Storage Unit 3 Installing the MSU 4 Maintaining the MSU 5 Notes 8 ...

Page 3: ...e operating environment to prolong disk life Constant monitoring of disk SMART parameters will enable warnings of potential problems therefore allowing maintenance to be scheduled to prevent potential disk failure The disks and fans are all field servicable This manual details the servicing operation The MSU is available in the following sizes 5 0 TB MSU 5 1000 GB drives 3 75 TB MSU 5 750 GB drive...

Page 4: ... located on the MSU Configuration CD which accompanies the unit Either Insert the CD containing the config file vidcfg ini into the CD drive of the DVR and select the software upgrade option via the DVR s Configuration menus Or Extract the the vidcfg ini file and copy into the etc directory of the DVR via FTP File Transfer Protocol client software i e Core FTP 2 Reboot the DVR IMPORTANT To success...

Page 5: ...icated Micros 2008 MSU Maintaining the MSU Opening the MSU 1 2 Lower the front flap on the MSU 3 Use the provided key to unlock the Draw Open the hinged front left flap and release the transportation screw ...

Page 6: ...Dedicated Micros 2008 MSU 43 Pull the drawer open 5 The drawer is mounted on two sliding runners These runners have a securing catch which needs to be released before the drawer will close ...

Page 7: ...Remove the screws and lift the hard drive up Retain the screws 3 The SATA and power connection are incorporated into one plug Remove the plug from the back of the drive 4 Replace the hard drive with a replacement unit from Dedicated Micros Secure the hard drive using the previously removed screws Note Remember the catch on the drawer slider needs to be unlatched to allow the drawer to close proper...

Page 8: ...ACE SATA ENVIRONMENTAL CONTROL Intelligent individual disk cooling Power supply 1 x 200W Internal Health monitoring Continuous Disk and Cooling fans maintenance Field maintainable HDD and fans with front panel access AC INPUT VOLTAGE 120v 60HZ 240v 50HZ Selectable operating temperature 5 C 45 C operating HUMIDITY 5 85 Non Condensing configuration 2U Rack Mount dimension mm 89mm H x 440mm W x 537mm...

Page 9: ...Dedicated Micros 2008 MSU Notes ...

Page 10: ...Dedicated Micros 2008 10 MSU Notes ...

Page 11: ...Dedicated Micros 2008 11 MSU ...

Page 12: ...a 20151 USA Dedicated Micros USA 23456 Hawthorne Blvd Suite 100 Torrance CA 90505 USA Dedicated Micros Australia PTY 5 3 Packard Avenue Castle Hill NSW 2154 Australia Dedicated Micros Asia PTY 16 New Industrial Road 03 03 Hudson Techno Centre Singapore 536204 Dedicated Micros Middle East Building 12 Suite 302 P O Box 500291 Dubai Internet City Dubai United Arab Emirates Dedicated Micros Malta Ltd ...

Reviews: