background image

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

DECOPROYEC 

C/Trilladores nº47 - Nave 4 y 5 (P.I. Los Molinos)  
C.P.: 02520 – Chinchilla de Montearagón 
(ALBACETE), Spain 
 
Tel. +34 967 261787 / +34 616 897845 
[email protected]

 

 

Summary of Contents for CP19

Page 1: ...REF 81 06 03 026 DECOPROYEC rev0 DECOPROYEC C Trilladores nº47 Nave 4 y 5 P I Los Molinos C P 02520 Chinchilla de Montearagón ALBACETE Spain Tel 34 967 261787 34 616897845 decoproyec decoproyec com ...

Page 2: ...19 Nozzles 6 mm 5 8 mm as an option Body Anodized external treatment Air consumption 110 l m at 2 5 bar 125 l m at 3 bar Funnel capacity 5 Litros nylon Weight 605 gr Air inlet CR Supply system Gravity Functioning Valve continuous air ATTENTION In order to ensure that the equipment characteristics correspond to those specified in your order please check it when you receive it and contact us in case...

Page 3: ... default configuration and the gun leaves the factory with it To change from the Continuous Air Mode to the Valve Mode follow these steps 1 Disassemble the product regulator no 12 of the exploded view and take the spring out no 13 of the exploded view 2 Insert an Allen key size 4 at the back of the needle whose cap has an Allen groove no 10 of the exploded view 3 Turn the Allen key clockwise to ti...

Page 4: ...e whose cap has an Allen groove no 10 of the exploded view 3 Turn the Allen key counterclockwise to unlock the cap Be careful when removing the cap enough to open the continuous air holes but it can NEVER protrude the needle 6 WORKING INSTRUCTIONS The size of the drop can be adjusted with the product regulator no 12 of the exploded view turning clockwise you get bigger drops and counterclockwise s...

Page 5: ... from the compressed air network before any repair Use the gun in a well ventilated area where there are no risks of explosion or fire Never exceed pressure of 8 bar Once the work is finished close the product regulator completely no 12 of the exploded view to prevent vaporization 9 WARRANTY CERTIFICATE 1 It extends only and exclusively against any manufacturing defect 2 The period of validity is ...

Page 6: ...ring 2 units 7 50150B Trigger 8 50586B Inox stud bolt 9 50152B Packing nut 10 50609 Joints complete kit 10a 10b 10c 10d 10e 11 50154B Bushing with regulator 12a 50607B Needle 12b 50601B Needle screw 13 50599B Spring 1 unit 15 50022B Air regulator as an option not included as standard 16 10CR1 4HB1 Female air inlet adaptor as an option not included as standard 17 50399 Seeger ring for the trigger l...

Page 7: ...CP19 7 Exploded view Rev 0 ...

Page 8: ...DECOPROYEC C Trilladores nº47 Nave 4 y 5 P I Los Molinos C P 02520 Chinchilla de Montearagón ALBACETE Spain Tel 34 967 261787 34 616 897845 decoproyec decoproyec com ...

Reviews: