5.5 Instantaneous water heater 

 
The instantaneous water heater is completely electronically controlled and heats the 
water as it flows. The electronic regulation and control unit detect the water flow, the inlet 
temperature and the temperature selector at the specified outlet temperature. The 
microprocessor calculates the required value and turns on the appropriate heat output. 
When closing the hot water valve, the heater is turned off independently and the 
electronic all poles system disconnected from the mains. The device consists essentially 
of the heating block, the power module with triacs, the electronic module, a safety 
temperature and pressure limiter and the pressure differential switch

.

 

 
Heating coils are used as a radiator, which are surrounded by flowing water directly. By 
this heating mode and with 0.5 litres of very low water content, a high efficiency is 
ensured. The amount of water is limited by a built-in flow control by fully open hot water 
valve to max.10l / min flow rate so that a suitable outlet temperature for the shower 
(about 40º C) remains. 
 
Thanks to the built-in temperature and pressure safety limiter, a double safety shut-off is 
reached by over pressure and over temperature. The pressure limiter triggers by a rise in 
pressure

 

to about

 

22 bars, the temperature limiter triggers at about 55º C in the intake 

and at about 70º C in hot-water outflow. In response of the pressure or temperature 
limiter the device is disconnected at once from the mains.  
 
Prior to press again the pushbutton on the safety temperature and pressure limiter,

 

the 

cause of the disorder is to be determined and resolved by a qualified person  
 

Summary of Contents for WM 400 V

Page 1: ...Guide book Water treatment instantaneous water heater system WM 400 V Producer deconta GmbH Im Geer 20 46419 Isselburg Description Instantaneous water heater system WM 400 V Type No 25 Serial No...

Page 2: ...echnical description 7 5 1 Intended use 7 5 2 Device description 7 5 3 Sewage pump 8 5 3 1 Version with 2 sewage pumps 8 5 4 Waste water filter system 9 5 5 Continuous flow water heater 11 6 Technical...

Page 3: ...neered equipment outside of the asbestos removal should be agreed upon beforehand with deconta deconta will help you with pleasure and will take then also the liability by the external original use In...

Page 4: ...airs maintenance and cleaning in particular in the field of electrical equipment should be realized by qualified staff or if necessary by the express service deconta in order to guaranty and keep the...

Page 5: ...ng over of the carrier or another supplier Please note the possible damages on the way bill additionally 3 2 Transport In order to avoid damages due to faulty handling or imprudence please handle with...

Page 6: ...purchased or rented unless other arrangements have been made Guide book Water treatment geyser Cartridge filter 50 1 Sieve element 220 4 2 Return delivery after the rental period To protect our custom...

Page 7: ...re they exit The deconta water treatment assumes the heating of the shower water and takes over the filtering of the contaminated sewage water 5 2 Device description water treatment The built in geyse...

Page 8: ...ng one automatic ensures that the pump is started and runs during the entire process A manual starting is possible with the key sewage pump start 5 3 1 Model with 2 waste water pumps Optionally the WM...

Page 9: ...ough the drain line To achieve a constant flow pump the fine filters have to be changed at a too strong fouling We recommend a filter change of the two fine filter at about 3 0 bar The pre filter is t...

Page 10: ...ameter Effectivity 1 0 77 84 3 2 0 97 90 9 3 1 22 93 5 4 1 54 95 0 5 1 93 96 2 6 2 44 97 4 7 3 07 98 5 8 3 87 99 7 9 4 87 99 8 10 6 14 100 0 11 7 74 100 0 12 9 75 100 0 13 12 28 100 0 14 15 47 100 0 1...

Page 11: ...rential switch Heating coils are used as a radiator which are surrounded by flowing water directly By this heating mode and with 0 5 litres of very low water content a high efficiency is ensured The a...

Page 12: ...tion Suction and pressure side Output power Instantaneous water heater 21 KW 6 2 Sewage pump Tension 230V 50 Hz Speed 2900 1 min Power 0 45 kW Weight 9 8 Kg Output max 31 5 l min max Medium temperatur...

Page 13: ...ter suction with the shower floor element Connect the drain hose connection with waste water and sewer 7 2 Preparing for operation Open fresh water intake Fill the sewage pump see chapter 8 2 Set the...

Page 14: ...In case of frost danger the stopped pump has to be emptied through the drain plug After a long standstill this is to check before restarting if the wheel has been blocked by deposits caused by impuri...

Page 15: ...n with stop 2 Sieve 3 Cap nut SW 24 4 Flow regulator with check valve The safety limiter Changes in the safety temperature and pressure limiters are not allowed In all the disorders we recommend to co...

Page 16: ...3 Output of the pump goes back Saturation rate of the filter too high Change filter Impeller of the pump does not turn Initial rotational resistance too high See chapter 7 Pump does not start during p...

Page 17: ...Infinitely adjustable shower water temperature 30 C and 60 C Electronic volume and temperature of the shower water Built in safety temperature and pressure limiter Three stage waste water filter syst...

Reviews: