Instruction manual
Compact
25.000
Seite 14
Starting position:
Connect to power
Chose a measuring point in the dirty area and connect the PE-tube 8 x 1 to the
negative pressure connection
Chose the measuring point in the clean area (adjoining room) and connect the PE-
tube 8 x 1 to the connection atmosphere
The unit is now ready for use.
Power switch to „ON“
Press
key
ON/OFF
IMPORTANT:
Press and hold the key for about 3 seconds
The last saved mode (AUTO / MANU)is automatically set and the fan starts
Automatic operation
In automatic operation the set value for the negative pressure in Pascal is entered with
the buttons „+“ and „-“ (display set value in automatic operation). By comparing the
entered set value with the permanently measured actual value (measured negative
pressure) the speed of the fan is automatically adjusted, i.e. the fan moves automatically
“up” or “down”.
Manual operation:
In manual operation the fan capacity is set with the buttons „+“ and „-“. The performance
in % and the measured negative pressure are shown in the display. In manual operation
the machine does not adjust automatically!
In case of power failure the control saves the date set last, starts after recovery
automatically and re-establishes the saved data.
Connection
Atmosphere
Connection
Negative pressure