DECKMA HAMBURG GmbH
Issue: 27.05.08
Instruction Manual OMD-2005
Page 8 of 25
5.0 CONSTRUCTION
There are 3 main parts which contained in an OMD-2005:
The computer unit is mounted into an epoxy powder painted steel housing
to protect the electronics of the display PCB with the data logger and the
main board PCB with the terminals for external connections.
The measuring cell is built out of an anodized all-aluminium body with inlet
and outlet block in stainless steel. This rugged cell contains the optical
electronic and correspond with the computer unit via a plugged data cable.
The valve assembly contains a special handle to sense the position of the
valve. This assembly is connected to the measuring cell by an easy to
handle fitting to enable the exchange of the cell for frequently adjustment
according the IMO requirements.
All components are mounted to a stainless steel mounting plate for easy wall or
bulkhead installation. It is also possible to split the computer unit from the
measuring cell if the available space is not sufficient. For this version divided
mounting plates are available.
ON
OMD-2005
Oil Monitoring Device
Alarm 1
Alarm 2
System
OK
DECKMA HAMBURG
www.deckma.com
S A M P L E 1 / 4 "
C L E A N W A T E R 1 / 4 "
O U T 1 / 4 "
D E C K M A H A M B U R G
D H 7 5 4 5 0
1 Computer
Unit
5 Handle
9 3/2
Way
Valve
2
Head Screw
6
Limit Switch
10
Mounting Plate
3 Fitting
7 Spacer
11
Desiccator
4
Measuring Cell
8
Valve Plate
12
Communication Cable
Fig. 1
StockCheck.com