SI-3C
™
U
ser
’s M
anual
25
Set Average time
(only applies to SVR type radars – the time measurement speeds are
averaged)
Send ASCII a XXX <CR>
Where XXX value =
000 -> instantaneous speed
001 -> 100 secs of averaging,
NOTE: Radar measurement time is 0 .0625 secs (16 times per second)
Radar responds back with ASCII “OK” <LF> <CR>
Poll speed
(only available if Radar is configured for polled mode)
Send ASCII *P<CR> or *<CR>
Radar responds with speed update
Reset to factory defaults
Send ASCII X <CR> or ASCII x <CR>
Radar will reset all configure items back to factory defaults and
save to flash .
Radar responds back with ASCII “FACTORY DEFAULTS” <LF> <CR> if
successful .
Save configure items to FLASH
Send ASCII F <CR>
Radar responds back with ASCII “OK FLASH SAVED” <LF> <CR> on
success or ASCII “FLASH FAILURE” <LF> <CR> on failure .
•
Please wait 2 seconds after the last configuration
command before disconnecting the power to allow the
SI-3C™ to record the setting in flash memory.
Get configure data <not implemented – future release>
Send ASCII c <CR>
Radar responds back with list of configurable items and values .