1.2.1 Power-Up Tests
The system runs the power-up tests each time you turn on the system. If the
system passes the tests, it responds with a display similar to the following:
KA45−A V1.0
08−00−2B−1A−0B−BB
16MB
>>>
1
2
3
4
5
1
Central Processing Unit (CPU) Name and Firmware Version Number—The
KA45 is the CPU in the Model 40 system; the KA47 is the CPU in the
Model 80 system. V1.0 is the firmware version number.
2
Ethernet Hardware Address.
3
Memory Size.
4
Status Bar—The completion mark ( | ) indicates the full extent of the
status bar. When the status bar reaches the completion mark, the power-
up test is complete. On some terminals, the status bars are displayed as a
line of number signs (#).
5
Console Prompt
1
.
1
The system may not display the console prompt if the default recovery action is set to
boot or restart. See the MicroVAX 3100 Model 40 and Model 80 Customer Technical
Information manual for more information on system defaults.
1–10 Troubleshooting and Diagnosing Problems