Chapter 2. RAID Array Controller
EK–SMCPO–UG. A01
2–5
Table 2–1 Controller Specifications (Continued)
Item
Specifications
Disk Warm Spare (not spinning)
Yes, global warm spare
Redundant Power Supplies
Yes
Redundant Controllers
Yes
Controller Failover
Yes, automatic
Controller Hot Spare
Yes (Active-Passive mode)
Controller Hot Swap
Yes
Cluster Support
Yes, Single (SCSI) bus cluster
Maximum number of units presented to
host
64
Maximum host port transfer speed
20 MHz
Command Queuing
Yes, 64 commands (host and disk SCSI chan-
nels)
Heterogeneous Multi-Host Support
Yes
Mixed Drive Types
Yes
Configurable Reconstruct Time
Yes
Stripe Size (chunk size)
Variable
Write through Cache
Yes, User Selectable (default)
Write Back Cache
Yes, User Selectable (optional)
Write on Top
Yes
Write Gathering
Yes
Battery Backup for Cache
Yes, Pedestal Uninterruptable Power Supply
(UPS)
Boot Capability
Bootable from RAID set (System dependent)
Number of Controllers /System
Two
Cache Support
Up to 256 MB (using two 128 MB industry-
standard, 72-pin, 36-bit, 60 ns SIMMS)
FCC Rating
Class B
Environmental
Temperature
5ºC to 50ºC operating, -40ºC to +60ºC non-
operating
Relative Humidity
10% to 95% non-condensing (operating), 5% to
90%, non-condensing (non-operating)
Physical Size
8.55” deep, 5.03” wide, 1.6” high
Power Requirements
5 VDC @ 3 A, peak; - 12 VDC @ 1 A, peak
Summary of Contents for DS-HSZ22-AA
Page 8: ......
Page 10: ......
Page 28: ......
Page 40: ...RAID Array 3000 Pedestal Enclosure 2 12 EK SMCPO UG A01 Figure 2 4 RAID 0 Write ...
Page 60: ...RAID Array 3000 Pedestal Enclosure 3 8 EK SMCPO UG A01 Figure 3 5 Replacing a Power Supply ...
Page 92: ......
Page 94: ......