Warning: 

The ash pan and content can be hot and must be store in a non- flammable 

container away from flammable material then disposed of only when they are completely 

cold and there no risk of causing a fire.

 

.  

 

 
 
Lighting The Stove With Solid Fuel 

 
Remove the H shaped woodburning plate if in place. 
Lay a fire of sticks and paper, establish the fire and then add the appropriate smokeless fuel 
and use the primary air control as the main control.  If using a mixture of wood and coal, 
balance the primary and secondary control to achieve the desired fire. 
 

When using solid fuel in this stove you must only use fuels recommended for enclosed 
appliances, Oil derivative fuels must not be used as this will shorten the life of the grate. 
The Ash pan will need emptying once a day. 

 
The stove will work best using the primary air control.  It is unlikely you will need to use the 
secondary air control which will only need to be opened slightly to keep the glass clear.  With 
suitable adjustment of the primary air control, a bed of smokeless fuel charged to the level of 
the fire retaining bars should burn well for about 1.5 - 2 hours before the need to riddle the fire. 

 

In the summer or when the stove is not being used for a long period of time, clear all the ash 
out and leave primary and secondary air vents open to prevent condensation. 

 
 
 
 
Please Note: 

When lighting the stove for the first time the paint on the stove will cure and give off a metallic 
smell.  It is advisable to ventilate the room ie. open the windows.  This will subside after the 
stove has been burning hot for at least 2 hours. 
 
The appliances have been assessed and are suitable for intermittent burning. 

 

Operation

 with the door open can cause excess smoke. The appliance must not be operated with 

the appliance door left open except as directed in the instructions.  

 
Pre-Season Check: 

 

 

The chimney needs to be swept at least once a year. 
The chimney must be checked at this stage for blockages before lighting i.e.: bird’s nests 
This is probably the time to have the chimney swept before the beginning of the seasons. 
Before lighting at the beginning of the season or after prolonged shutdown periods, check the 
door seals are in good condition; the steel insulating plates/fire bricks are in good condition and 
baffle plate is in position. 

Summary of Contents for Hembury 5 SE

Page 1: ...lean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been authorised in Regulations and that appliances used to burn solid fuel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations The D...

Page 2: ...ts of such appliances Extractor Fans When operating an extractor fan in the same room or space as the appliance the extractor fan could cause the stove not to function properly and pull dangerous fume into the room This must be checked by a trained qualified engineer before using the stove Wood Suitable fuels Dry wood 18 moisture content or below must be used or the stove and flue will tar up and ...

Page 3: ...el Pull fully out for maximum air flow to the fire and fully in to close the air flow The secondary air wash control is indicated with double slots This controls the preheated air wash once the fire in the stove is established this is the control that should be used to control the fire when burning wood The secondary control works as follows Pull out fully for maximum air flow into the fire and fu...

Page 4: ...commended that you do not leave the appliance unattended until it is certain that the logs are burning well with a sustained flame Do not load the fuel above the log retainer Please note If there is insufficient burning material in the fire bed to light a new fuel charge excessive smoke emission can occur Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the ...

Page 5: ...to the level of the fire retaining bars should burn well for about 1 5 2 hours before the need to riddle the fire In the summer or when the stove is not being used for a long period of time clear all the ash out and leave primary and secondary air vents open to prevent condensation Please Note When lighting the stove for the first time the paint on the stove will cure and give off a metallic smell...

Page 6: ...If the stove starts emits fumes into the room 1 Check there is no blockage or restriction in the flue 2 Check the external air vent is not blocked 3 Check the baffle plate has not dislodged itself from the stove 4 Call an engineer If the stove does not perform properly this is could be due to unseasoned wet wood or too much ash in the firebox In the case of the stove malfunctioning shut all vents ...

Page 7: ...meet current building regulations Stoves must be fitted to BS8303 BS6461 PT1 2 1984 building regulations All local regulations including those referring to national and European standards need to be complied with when installing the appliance N B A suitably qualified person must fit the stove i e a HETAS engineer or with the supervision of building control As with all stoves fireguards must be ins...

Page 8: ...stove is installed into a fire opening made of non combustible materials we recommend a minimum of 150mm gap to the sides and 300mm above from non combustible materials The appliance must be installed on a floor with an adequate low bearing capacity If the construction doesn t meet the existing prerequisite the floor must be reinforced or a load distributing plate could be fitted Table of distance...

Page 9: ...swept through the stove an access door on the first length of flue must be installed for cleaning access The Hembury 5 SE model requires a 125mm 5 first length of flue then stepping up into a minimum of 150mm 6 liner When the Hembury 5 SE has a smoke except air slider fitted the flue liner can be reduced to 125mm 5 We strongly advise a 150mm 6 flue liner be fitted when possible Diagrams showing th...

Page 10: ...adhered to The baffle plate is in the right position A smoke test has been done to check the chimney is clear Data Plate All stoves are numbered and performance marked on a data plate which is found on a swinging arm located at rear of the stove Air Vent Under part J of building regulations an air vent of the appropriate size must be fitted for all stoves with a kw rating of over 5kw Very air tigh...

Page 11: ...ant Carbon Monoxide Alarm must be fitted Table of mean flue temperatures with closed doors Stove Type Flue gas temp down stream of spigot closed doors Wood logs Ancit Hembury 5 SE 233 C 289 C Flue Gas Mass Flow Stove Type Flue gas mass flow g s Wood logs Ancit Hembury 5 SE 3 7 6 7 Stove Performance Hembury 5 SE Wood burning 5kW nominal 83 Net Efficiency Solid Fuel Ancit 5kW nominal 67 Net Efficien...

Page 12: ...uct Hembury multifuel heating stove product range Steel bodied stove fitted with cast iron doors Supplied in various sizes to give a range of heat output options Are in conformity with the provisions of the following EC Directive S when installed in accordance with the installation instructions in the product documentation 98 106 EEC 305 2011 Construction Products Directive other directive And the...

Page 13: ...Ancit 0 31 5 3Kw 83 Wood 5Kw 67 8 Ancit 6931 2 Hembury 5 Slimline STDFHE5SLMF Co 13 0 Wood 0 44 Ancit 0 22 5Kw 81 6 Wood 4 9Kw 75 8 Ancit 60424 1 Hembury 6 STDFHE6MF Co 13 0 Wood 0 44 6 5Kw 79 6 Wood 6038 4 Hembury 8 STDFHE8MF Co 13 0 Wood 0 28 8 4Kw 76 4 Wood 60424 2 Release of dangerous substances None Surface temperature Satisfies Mechanical resistance to carry a chimney flue Maximum weight to ...

Page 14: ...installer for any relevant guarantees applicable to the installation Dean Forge Fabrication Ltd will not be held liable for any consequential or incidental loss damage or injury however caused Claims under this guarantee should be first made through your retailer This guarantee is only applicable in the UK Nothing in this guarantee shall effect your statutory rights Exclusions The following consum...

Page 15: ...15 ...

Page 16: ...STRATION Name Address Phone Number Suppliers Details Name Address Phone Number Installers Details Name Address Phone Number HETAS Registration Number Dean Forge Fabrication Ltd Dean Prior Buckfastleigh Devon TQ11 0LS ...

Reviews: