Extractor fans when operating in the same room or space as the appliance may
cause problems.
Air vent inlet grills must not be inadvertently blocked.
Air vents must not be fitted in positions where they can be inadvertently covered up.
As from the 1
st
October 2010 a compliant Carbon Monoxide Alarm must be fitted
Table of mean flue temperatures with closed doors
Stove Type
Flue gas temp down stream of spigot, closed doors.
Wood logs
Ancit
Hembury 5 SE
233°C
289°C
Flue Gas Mass Flow
Stove Type
Flue gas mass flow (g/s)
Wood logs
Ancit
Hembury 5 SE
3.7
6.7
Stove Performance
Hembury 5 SE Wood burning 5kW nominal
83% Net Efficiency
Solid Fuel (Ancit)
5kW nominal
67% Net Efficiency
All stoves are tested to nominal outputs and will well exceed these kilowatt ratings.