HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-20
1.7.6 Replacing the Pilot Assembly
1.
Remove the pilot tubing from the bottom of the pilot assembly.
2.
If the pilot is an electronic ignition pilot, disconnect the ignition cable and the sense wire.
3.
Remove the pilot mounting screw(s) from the pilot mounting bracket and remove the pilot.
4.
Reverse the procedure to replace the pilot assembly.
NOTE:
The above procedure is applicable to standing pilot, electronic ignition, and
trailing pilot assemblies.
1.7.7 Replacing the Frypot
1.
Open fryer doors and remove filter pan (if applicable). Ensure controller and all power switches
are off. Drain and dispose of or store oil from all frypots prior to moving fryer.
DANGER
Hot cooking oil will cause severe burns. Never attempt to move this appliance when
filled with hot cooking oil or to transfer hot cooking oil from one container to
another.
2.
Turn gas valve off, then turn gas off at supply valve or meter. Disconnect supply line from gas
manifold at rear of fryer.
NOTE:
If restraints are installed on the fryer, disconnect restraints prior to disconnecting
the gas supply line.
3.
Unplug fryer from electrical supply source.
4.
Remove fryer door for easier access to the temperature probe. First, remove top hinge from
bracket. Then, lift door off bottom hinge pin.
5.
Remove the basket hanger from the flue cap by lifting
up and off of fryer. Some units may have a built-in
flue deflector on the basket hanger. Units with basket
lifts will require the removal of the lift arms prior to
removing the basket hanger.
Removing the basket hanger from the flue cap.