![DEA SYSTEM LATO 220CEN Operating Instructions And Warnings Download Page 8](http://html1.mh-extra.com/html/dea-system/lato-220cen/lato-220cen_operating-instructions-and-warnings_2461033008.webp)
22
SCHEMA ELECTRIC POUR MOTEURS 400V
AVEC PLATINE EXTERNE
ST
ART
TX
RX
PHO
TO 1
COM
N.C.
N.O.
L3
L2
L1
400V 3~ 50Hz ±10%
RG58
2 x 0,5 mm
2
4 x 0,5 mm
2
N.O
.
FC
A1
FC
C1
ST
OP
M
ARR
ON
NOIRE
GRIS
COM
M
ARR
ON
VER
T
M
ARR
ON
NOIRE
GRIS
COM
M
ARR
ON
VER
T
F9
F8
400V 3~
11
12
13
14
15
16
17
18
19
20
21
22
23
24
1
2
3
4
5
6
7
8
9
10
WARNING
LOCK
FLASH
230V
0V
24VSIC
24V
AUX
COM
SIC
FC
A
FC
C
PED
FO
TO
ST
OP
ST
AR
T
COM
L1
L2
L3
T1 (
CH)
T2 (
AP)
T3 (
COM)
26
25
3 x 1,5 mm
2
CLIGNOTANT À
LED 230V ~
75mA max 50 Hz
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
3 x 0,22 mm
2
3 x 1,5 mm
2
M
ARR
ON
NOIRE
GRIS
CÂBLAGES INTERNES PRÉDISPOSÉS PAR L’USINE
CÂBLAGES EXTERNES PRÉDISPOSÉS PAR L’INSTALLATEUR
ENC
M1
FLASH
230V
ANTENNE
BLANCHE
BLANCHE
Summary of Contents for LATO 220CEN
Page 12: ...50 6 3 3 3 1 3 1 1 105 118 182 121 296 414 119 27 ...