16
De Rigo Refrigeration s.r.l.
TECHNICAL INFORMATION: main adjustment parameters.
TECHNICAL DOCUMENTATION INSERTED IN COUNTER
Each counter has a yellow envelope placed inside near the serial number plate. This envelope contains
all the required technical documentation, such as:
- Use and maintenance manual;
- Declaration of conformity;
- Quality control sheet;
- Test inspection certificate;
- Counter wiring diagram;
- Reactor board diagram (only if foreseen);
- Manual of controller installed on electric panel (only if foreseen);
- Controller parameters map (only if present);
- Various documentation such as: motorised night blind instructions, electronic valve instructions,...
(only if present)
.
N.B.: At times, labels with additional instructions and/or recommendations are applied on some counter
surfaces
.
Par.
DESCRIPTION
Adjustment
range
SAPPHIRE
Cl. H
(+1/+10°C)
Cl. M2
(+5/+8°C)
Cl. M1
(-1/+5°C)
SET Temperature control setting
LS÷US
2.0
0.0
-2.0
HY
Differential
0,1÷25,5
4.0
4.0
4.0
dtE
End defrost temp.
-50,0÷50,0 °C
8.0
8.0
8.0
idF
Defrost cycles interval
1÷120 hours
12.0
12.0
12.0
MdF Maximum defrost duration
0÷255 min
50.0
50.0
50.0