DDS Calorimeters CAL3K-A Installation Manual Download Page 21

DDS CALORIMETERS 

www.ddscalorimeters.com

 

 

Manufacturers of CAL2K/CAL3K Oxygen Bomb Calorimeters 

 

 

CAL3K-A INSTALLATION GUIDE V1.1  |  

www.ddscalorimeters.com

  |  [email protected] 

for any damages, consequential, indirect or direct, or loss whatsoever, resulting out of electrical shock, Vessel 

explosion, or any other cause. 

 

WARRANTY – REPAIRED PRODUCTS 

Any “dds” scientific product that has been repaired has a warranty period of 30 Days from date of shipment for the 

Repair request only. If something else goes wrong that is not part of the original Repair, the warranty does not apply. 

Each product that is sent to “dds” for Repair is tested and checked and leaves “dds’s” Factory in 100% working order. 

It is the Owner’s responsibility to inspect any repaired product on receipt thereof and confirm in writing, any faults, 

errors or problems with the said product.  If a fault, error or problem is reported after the 30 Day warranty period, 

and “dds” finds that the product has been damaged and requires another repair, the full cost of repair will be 

applicable and paid for by the Owner. 

 

GENERAL – WARRANTY VOID 

All serial numbers on any relevant “dds” Scientific product need to remain on the product at all times, or warranty 

will be void.  Warranty will also be void if any of the branding stickers or decals have been removed and/or the 

colour of the Scientific product has been changed in any way. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for CAL3K-A

Page 1: ...cturers of CAL2K CAL3K Oxygen Bomb Calorimeters CAL3K A INSTALLATION GUIDE V1 1 www ddscalorimeters com calo ddsystems co za CAL3K A INSTALLATION GUIDE VERSION 1 1 MANUFACTURED BY DIGITAL DATA SYSTEMS...

Page 2: ...A CALORIMETER WITH EXTERNAL oxygen filling 6 THE 3K 2 AIR COOLER 6 THE 3K 5 BAYONET VESSEL 7 THE CAL2K 3 OXYGEN FILLING STATION 7 7 UNPACKING AND INSPECTION 7 SETTING UP 8 PREREQUISITES 8 SITE SELECT...

Page 3: ...INATE USER TEST 16 16 CAL3K A USER TEST 16 16 SUBJECT HELP 16 OTHER KEYBOARD COMMANDS 16 ABORT 16 FIRE MANUAL 16 CALIBRATION 16 READ RESULT 17 CONNECTING TO A BALANCE 17 17 CALIBRATION 18 INTELCAL CAL...

Page 4: ...and the factory calibration But there is more Information and capability This is not explained here but in an ON LINE version It is safe to say that you need a PC or laptop to change from the basic o...

Page 5: ...Bottle 2 3K A INST CAL3K A Installation Guide Printed 1 3K 2 CAL3K Air Cooler 1 3K 2 KT CAL3K Air Cooler Installation Kit 1 Included in Kit 3K SM Power Supply 1 KETTLECORD Mains Cable 220 V 1 CAL2K 3...

Page 6: ...e calorimeter and the lid is closed The rest is automatic Width 270mm Height 200mm Depth 380mm Weight 8kg Power 220 240V 12W THE 3K 2 AIR COOLER The air cooler requires no water piping or other resour...

Page 7: ...ight 150mm Weight 1 9kg THE CAL2K 3 OXYGEN FILLING STATION The oxygen filling station is connected to the oxygen bottle via a regulator The regulator reduces the bottle pressure to 30bar which is adju...

Page 8: ...contact your agent SETTING UP PREREQUISITES Prior to installation of the CAL3K A System the User must provide the following 1 A mains outlet for the 3K 1_A Calorimeter and a mains outlet for the 3K 2...

Page 9: ...HE FILLING PRESSURE IS ADJUSTABLE on the regulator the filling speed is adjustable on the filling station REMEMBER You may fill the Vessel LESS than 3000KPA but NEVER more than 3000KPA FILLING STATION...

Page 10: ...to the outside or any suitable scrubber to prevent the burned gas to enter the room COOLER 3K 2 Electrical shock There are no user serviceable parts inside VESSEL 3K 5 The Vessel has been pressure tes...

Page 11: ...DS CALORIMETERS www ddscalorimeters com Manufacturers of CAL2K CAL3K Oxygen Bomb Calorimeters CAL3K A INSTALLATION GUIDE V1 1 www ddscalorimeters com calo ddsystems co za CAL3K A REAR PANEL CONNECTION...

Page 12: ...test is logged into the Event Logging and the User Test Log It is recommended to repeat the hardware once a day or once per shift The hardware test takes approximately 1 minute to complete NOTE While...

Page 13: ...CAL3K A hardware test The unit cycles through the following steps and stops for operator action or when a fault is encountered Will stop the test The results of the test are logged together with the V...

Page 14: ...password Function keys They serve as a shortcut to the keyboard commands The following function keys are used F1 Mass entry F1 Enter 0 xxxx Enter F2 Sample Identification F2 Enter mysampleId Enter F3...

Page 15: ...6 character or shorter string SPIKE MASS Enter the weight of the spike mass here A spike mass of zero disables spiking For details of spiking see www ddscalorimeters com BALANCE MASS The supplied bala...

Page 16: ...nit waits for an action a more detailed subject help is available to explain what is needed Press whenever something does not progress and read the comments OTHER KEYBOARD COMMANDS Here are some handy...

Page 17: ...e stable balance weight should show on the display If you press Enter then the mass is locked See MASS ENTRY to unlock it PERFORM THE FIRST SAMPLE The object of this exercise is to check that everythi...

Page 18: ...e are many additional steps and procedures that you can do whilst running an actual CV sample You will find these How to Steps via the On line Help Guide available on the website www ddscalorimeters c...

Page 19: ...rocedure with the second vessel The calibration data set is stored in the vessel calibration history for the chassis number ROUTINE SAMPLE DETERMINATION The procedure is the same If you perform multip...

Page 20: ...be binding on dds unless recorded in writing and signed by a duly authorised officer of the company dds agrees to repair and replace with a new or remanufactured part any part other than those exclud...

Page 21: ...hat is sent to dds for Repair is tested and checked and leaves dds s Factory in 100 working order It is the Owner s responsibility to inspect any repaired product on receipt thereof and confirm in wri...

Page 22: ...AME OWNER S CUSTOMER S COMPANY NAME AUTHORISED BY INSTALLED AT TEL NO FAX NO CONTACT PERSON INSTALLED BY DATE INSTALLED REPRESENTATIVE OF DEALER AGENT CUSTOMER ORDER NUMBER AND DATE INSTALLATION DETAI...