PRELIMINAR
Y
31
TROUBLESHOOTING
CONDITION CHECK
No Bake
No Broil
No Clean
Not Locking and Un-Locking
Burners Not Lighting
Cooking Complaints
Bake igniter 3.0 amp to 3.3 amp draw ATC continuity
Oven T-Stat contacts
Main gas valve “OFF”
Selector switch contacts 30 – 33: 40 – 43
Dual safety valve continuity
Broil igniter 3.0 amp to 3.3 amp draw HTC continuity
Oven T –Stat contacts
Main gas valve “OFF”
Selector switch contacts (3-31;30-34;56-36;57-37;40-42)
Dual safety valve continuity
See “Clean Relay Section”
See motorized latch
See above
See motorized latch
See “Clean Relay Section”
Check supply voltage 120 VAC
Check for spark at burner
Igniter dirty
Check igniter switches
Check igniter module
Check operating gas pressure
See “Cooking Section”