ANTI-TIP DEVICE INSTALLATION INSTRUCTIONS
ANTI-TIP DEVICE INSTALLATION
All ranges must have an anti-tip device correctly installed
as per these instructions. If you pull the range out from
the wall for any reason, make sure that the device is
properly engaged when you push the range back against
the wall. If it is not, there is a possible risk of the range
tipping over and causing injury if you or a child stand, sit
or lean on an open door.
INCLUDED PARTS:
Included with this kit are: (4) #10 x 2” wood screws, (1)
Anti-tip bracket, and (1) Installation Instructions.
INSTALLING THE KIT:
Instructions are provided for wood and cement floors.
Any other type or construction may require special instal-
lation techniques as deemed necessary to provide
adequate fastening of the Anti-tip bracket to the floor
and wall. The use of this bracket does not preclude
tipping of the range when not properly installed.
WOOD CONSTRUCTION:
Place the bracket against the back wall, into the right rear
corner where the range is to be located. Leave a gap
between the wall (or side of range) and the bracket of
3/4”. Drill (2) 1/8” diameter pilot holes in the center of the
small holes. A nail or awl may be used if a drill is not
available. Fasten the bracket securely to the floor and
wall. See Fig. 6.
Concrete or cement construction:
HARDWARE REQUIRED: (2) sleeve anchors, lag bolts, and
washers (not provided). Locate the bracket as described
above. Drill the recommended size holes for the
hardware. Install the sleeve anchors into the holes and
then install the lag bolts through the bracket. The bolts
must be properly tightened as recommended for the
hardware. Fasten the bracket securely to the floor and
wall.
ONCE INSTALLED:
Complete the range installation per the instructions
provided with the product. Check for proper installation
of the Range and Anti-tip device by grasping the back of
the unit and carefully attempt to tilt the range forward.
WARNING
ALL RANGES CAN TIP
INJURY COULD RESULT
INSTALL ANTI-TIP
BRACKET PACKED
INSIDE OVEN
SEE INSTRUCTIONS
Fig. 7
Fig. 6
(2) Large Holes for
Concrete Installations
(2)Small Holes for
Wood Installations
(2) Wood Screws into
Back Wall (All
Installations)
Back
Wall
RIGHT SIDE OF
WA
LL OR RANGE
3/4”
THE MANUFACTURE WILL NOT PAY
FOR ANY DAMAGE DO TO MISSING OR
IMPROPERLY INSTALLED ANTI-TIP