background image

6

INSTALLING THE ANTI TIP DEVICE

FOR FREESTANDING INSTALLATIONS

Step by step instructions for locating the po-

sition of the bracket:

1) Decide where you want to place the drawer refrigerator.

Slide it into place, being careful not to damage the floor,

leaving 1" (2.5 cm) of clearance from the rear wall to allow

room for the anti-tip bracket.

2) Raise the rear leveling legs approximately 

1

4

" (6 mm) to

allow engagement with the anti-tip bracket. Level the unit

by adjusting all the leveling legs as required. Turning the

leveling leg counterclockwise will raise the unit and clock-

wise will lower the unit.

3) Make sure the refrigerator is in the desired location, then

mark on the floor the rear and side corner of the cabinet

where the anti-tip bracket will be installed. If the installation

does not allow marking the rear corner of the cabinet, then

make temporary lines on the floor marking the front corner

of the cabinet, excluding the drawer. Slide the refrigerator

out of the way. From the temporary line extend the sidewall

line back 21

1

2

" (54.6 cm) as shown in Figure 7.

4) Align the anti-tip bracket to the marks on the floor so

the side of the bracket lines up with the side of the cabinet

mark, and the "V" notches on the anti-tip bracket line up

with the end of the 21

1

2

" (54.6 cm) line (Rear of cabinet

line).

5) Fasten the anti-tip bracket to the floor using the supplied

screw. (See Figure 7).

6) Slide the cabinet back into position, making sure the rear

cabinet leveling leg slides under the anti-tip bracket engag-

ing the slot.

Bottom View of

Refrigerated 

Drawer Unit

Anti-Tip

Bracket

Leveling Leg

Front of cabinet

21

1

2

"

(54.6 cm)

Figure 6

!

WARNING

ALL APPLIANCES CAN TIP

RESULTING IN INJURY.

INSTALL THE ANTI-TIP

BRACKET PACKED WITH

THE APPLIANCE.

FOLLOW THE INSTRUC-

TIONS BELOW

Floor Mount Installation

The anti-tip bracket is to be located on the floor in the left 

or right rear corner of the refrigerator drawer as shown in 

Figure 6.

!

CAUTION

NOTE

Any finished flooring should be protected with appropriate 

material to avoid damage when moving the unit.

If installing on a concrete floor, concrete fasteners are 

required, (not included with the anti-tip kit).

Anti-Tip Device

!

WARNING

If your refrigerator is not located under a counter 

top (free standing), you must use an anti-tip device 

installed as per these instructions. If the refrigerator is 

removed from its location for any reason, make sure 

that the device is properly engaged with the anti-tip 

bracket when you push the refrigerator back into the 

original location. If the device is not properly engaged, 

there is a risk of the refrigerator  tipping over, with the 

potential for property damage or personal injury. 

Summary of Contents for RF24DE4

Page 1: ...RF24DE4 OUTDOOR REFRIGERATOR DRAWERS USER INSTALLATION GUIDE US CA ...

Page 2: ...le conditions and situa tions that may occur Common sense caution and care must be exercised when installing maintaining or operat ing this appliance Recognize Safety Symbols Words and Labels CAUTION Hazards or unsafe practices which could re sult in personal injury or property product damage NOTE Important information to help assure a problem free installation and operation CONTENTS WARNING WARNI...

Page 3: ...least 24 hours before plugging in This will assure oil returns to the compressor Plugging the appliance in immediately may cause damage to internal parts Help Prevent Tragedies Child entrapment and suffocation are not problems of the past Junked or abandoned refrigerators are still dangerous even if they sit out for just a few hours If you are getting rid of your old refrigerator please follow the...

Page 4: ... area to not be obstructed and the grille openings kept clean See Figure 1 The use of a custom made grille is not recommended as it may restrict air flow Leveling Legs Adjustable legs at the front and rear corners of the appli ance should be set so the unit is firmly positioned on the floor and level from side to side and front to back The over all height of your DCS appliance may be adjusted betw...

Page 5: ...are generally not used on circuits with power equip ment that must run unattended for long periods of time un less required to meet local building codes and ordinances Electrical Connection A grounded 115 volt 15 amp dedicated circuit is required This product is factory equipped with a power supply cord that has a three pronged grounded plug It must be plugged into a mating grounding type receptac...

Page 6: ...bracket line up with the end of the 211 2 54 6 cm line Rear of cabinet line 5 Fasten the anti tip bracket to the floor using the supplied screw See Figure 7 6 Slide the cabinet back into position making sure the rear cabinet leveling leg slides under the anti tip bracket engag ing the slot Bottom View of Refrigerated Drawer Unit Anti Tip Bracket Leveling Leg Front of cabinet 211 2 54 6 cm Figure 6...

Page 7: ...uit Not shared with other appliances 5 When initially loading your new product or whenever large quantities of warm contents are placed within refrigerated storage compartment minimize drawer openings for the next 12 hours to allow contents to pull down to compartment set temperature 6 Maintaining a relatively full storage compartment will require less appliance run time than an empty compart ment...

Page 8: ... 88 3 cm 2323 32 60 2 cm 267 32 66 6 cm 395 32 99 5 cm Figure 8 Figure 8a PRODUCT DIMENSIONS If necessary to gain clearance inside the rough in opening a hole can be cut through the adjacent cabinet and the power cord routed through this hole to a power outlet Another way to increase the available opening depth is to recess the power outlet into the rear wall to gain the thickness of the power cor...

Page 9: ...ired for built in applications Figure 9 Depth dimension of rough in opening may vary depending on each individual installation To recess entire drawer F dimension plus 1 2 5 cm for thickness of power cord plug is required Minimum rough in opening required is to be larger than the adjusted height of the cabinet A grounded 15 amp dedicated circuit is required Follow all local building codes when ins...

Page 10: ...bbath Mode Press and hold for 5 seconds and release The oF oC symbol will flash briefly after 5 seconds Interior light and display will go dark and remain so until user resets mode unit continues to operate Disable Sabbath Mode Press and release Display and interior light return to normal operation Temperature displayed reflects actual temperature inside unit If the temperature displayed is differ...

Page 11: ...uuming or mop ping near the front of the appliance Damage to the grille can occur 3 Periodically clean the interior of the appliance as needed Front Grille Be sure that nothing obstructs the required air flow open ings in front of the cabinet At least once or twice a year brush or vacuum lint and dirt from the front grille area see page 4 SHOCK HAZARD Disconnect electrical power from the appliance...

Page 12: ...to remove any residual chemicals 15 Thoroughly clean the exterior with a cleaner approved for stainless steel Do not use any abrasive cleaners or scouring pads See Stainless Steel Maintenance on page 13 16 Any mounting hardware fasteners that are showing signs of corrosion should be replaced 17 Once the exterior has been thoroughly cleaned you may want to apply a coating of car wax to help protect...

Page 13: ...ild mixture of ammonia Rub bing should to the extent possible follow the polish lines of the steel and always insure thorough rinsing after cleaning Although some products are called stainless steel clean ers some may contain abrasives which could scratch the surface compromising the protective chrome oxide film and some many contain chlorine bleach which will dull tarnish or discolor the surface ...

Page 14: ...alling for service The problem may be something very simple that can be solved without a service call However it may be required to contact your dealer or a qualified service technician TROUBLESHOOTING AND WARRANTY Limited Warranty When you purchase any new DCS Refrigeration Product you automatically receive a One Year Limited Warranty covering parts and labor for servicing within the 48 main land...

Page 15: ...NTY Limited Warranty How Long Does this Limited Warranty Last Our liability under this Limited Warranty expires One Year from the date of purchase of the Product by the first consumer Our liability for repair of defects in any sealed refrigeration system compressor evaporator condenser filter dryer and connecting tubing extends an additional Four Years for a total of Five Years from the date of pu...

Page 16: ...ge at any time The product specifications in this guide apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time For current details about model and specification availability in your country please go to our website or contact your local Fisher Paykel dealer ...