13
INSTALLER FINAL CHECKLIST:
GRILL BURNER FLAME HEIGHT:
To access the grill burner air shutters first remove the valve panel by removing the four screws on the
corners of the valve panel. Remove the control knobs. Pull the valve panel outward while unplugging
the igniter. With a screw driver, loosen the lock-screw on the face of the air shutter. Light the burner
and adjust according to the directions above. Access for the power burner air shutters is through the
top after removing the top burner grate (See Fig. 08).
BURNER AIR ADJUSTMENT:
Each grill burner is tested and adjusted at the factory prior to shipment; however, variations in the local
gas supply or a conversion from one gas to another may make it necessary to adjust the burners. The
flames of the burners (except the rotisserie burner) should be visually checked and compared to that
of the drawing in Fig.07 and Fig. 09. Flames should be blue and stable with no yellow tips, excessive
noise or lifting. If any of these conditions exist, check if the air shutter or burner ports are blocked by
dirt, debris, spider webs, etc. Proceed with air shutter adjustment. The amount of air which enters a
burner is governed by a sheet metal cup or disk at the inlet of the burner called an air shutter. It is
locked in place by a set screw which must be loosened prior to lighting the burner for adjustment.
❏
Specified clearances main -
tained to combustibles.
❏
Nylon straps removed from
burners.
❏
All internal packaging
removed.
❏
Knobs turn freely, bezels
centered.
❏
Each burner lights satisfa-
torily, individually or with
adjacent burner lit.
❏
Air shutters adjusted.
❏
Adjustable low setting satis-
factory.
❏
Drip pan in place properly
and sliding freely.
❏
Pressure regulator
connected and set for
4.0"W.C. Natural, 11.2" W.C.
LP gas.
❏
Manual shut-off valve
installed and accessible.
❏
Unit tested and free of leaks.
❏
User informed of gas supply
shut-off valve location.
n
PLEASE LEAVE THESE
INSTRUCTIONS WITH THE
USER.
n
USER, PLEASE RETAIN
THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
1-1/2"
3/8"
Venturi
Tube
Flash
Tubes
Burner
Hanger
Lighter
Ports
Air
Shutters
Igniter
INSTALLER CHECKLIST/BURNER ADJUSTMENTS
FIG. 07 Burner Flame Height
FIG.8 Power Burner Air Shutters
Summary of Contents for BGA27-BQ
Page 1: ...THE PROFESSIONAL 27 BGA GRILL Use and Care Guide MODELS BGA27 BQ BGA27 BQR ...
Page 7: ...6 GRILL MODELS ROTISSERIE BGA27 BQ BGA27 BQR ...
Page 31: ...30 WIRING DIAGRAM FOR BGA27 BQ 16281 02 16281 03 18349 18353 ...
Page 32: ...31 WIRING DIAGRAM FOR BGA27 BQR 16282 01 16281 02 16281 03 18350 18353 ...