5
INSTAllATION
MAkE CUTOUT AND INSTAll SUPPORT STRUCTURE
Make a cut-out in your cabinet or island with the following dimensions (Fig. 3):
1.
Place 2 X 4s to provide support for the Access Drawers structure in the locations indicated in the figure below (Fig. 4).
2.
Board lengths are provided in the table below (Fig. 5).
3.
when installing your support boards, be
4.
sure they are level.
Ensure that the bottom of the center
5.
divider rests on top of the support
boards as shown (Fig. 4).
Fig. 5
Fig. 4
island cutout
1/2" Bottom of center divider to
C
B
A
A
B
E
D
Sticker location of
Model, Serial, Code Number
*
cUTOUT DIMeNSIONS
Model
A
(-0,+1/8”)
B
(-0,+1/8”)
c
D
ADR148 46”
20”
1.0” min.
1.0” min.
ADR136 34”
20”
1.0” min.
1.0” min.
ADR130 28”
20”
1.0” min.
1.0” min.
ADR124 22”
20”
1.0” min.
1.0” min.
NOTE: Each corner of the cutout should be 90º for the Access Drawers to fit properly.
SUPPORT BOARD DIMeNSIONS
Model A
B
c
D
e
48”
2 X 20” 1-1/2”* 3-1/2” min. 14 12
36”
20”
1-1/2”* 3-1/2” min. 14 –
30”
2 X 20” 1-1/2”* 3-1/2” min. 14 12
24”
20”
1-1/2”* 3-1/2” min. 14 –
To ensure proper drawer operation, be sure
your support boards are flat & level.
*Dependent on application. Top of 2x4’s
must be 1/2” above the bottom edge of
the cutout.
Fig. 6
For proper
support & drawer
operation, insure
that support
boards are level
front to back &
side to side.
Support Board (typical)
Support Boards
(typical)
FRONT VIew (TyPIcAL)
eND VIew (TyPIcAL)
Fig. 3
A
90º
B
Vent*
Vent*
Vent*
C
D
* Island installation to use minimum of 3 vents
providing 10 sq. in. per vent (typical).