Power On the Transmitter
Ensure region number in globe icon on transmitter matches
that on the receiver startup screen.
Install batteries in the SE 12 kHz transmitter.
Calibration Menu
Calibration is necessary prior to first-time use and before using a
different transmitter, receiver, or drill head. Calibrate in an
interference-free environment and with the transmitter in a housing.
Use a tape measure to check calibration daily.
1.
Place transmitter in a housing on level ground 3 m from receiver
(measure from inside edge of receiver as shown).
2.
Record signal strength for future use.
3.
From the Main menu, select
Calibration
,
1PT CAL
, and click to
calibrate.
4.
Verify calibration by moving receiver ±1.5 m and holding trigger
to tak
e
another depth/distance reading.