Steps Required Before Drilling

1.

Scan the jobsite for interference.

2.

Pick the frequency bands.

3.

Pair the locator with the transmitter.

4.

Verify data range.

5.

Calibrate both bands.

6.

Check Above Ground Range.

1. Scan the Jobsite

a.

With the transmitter off, select

Transmitter/FO

from the Main menu,

then

Frequency Optimization

(FO)

. The FO will show active

interference (noise) readings for current bands. Select

Scan/rescan

to see nine newly optimized bands.

1. Current bands

2. Selector
3. Band number
4. Maximum noise level
5. Up band
6. Down band
7. Scan/rescan
8. Pair
9. Exit

Frequency Optimization Results

Run the FO for each new project to select an optimal set of
frequencies for each band every time.

b.

With the FO results displayed, walk the locator along the bore path
while observing the noise readings. Mark those points where
significant increases occur.

If noise levels rise substantially at any point along the bore, consider
selecting and pairing one band (see next step) that performed well up to
this point. Cancel calibration, and select Transmitter/FO to repeat

Step 1

- Optimize

. Perform a new scan, select and pair a second band for use in

this higher-interference area.

- 2 -

Summary of Contents for DigiTrak Falcon F2

Page 1: ...Telemetry channel 2 Transmitter Tx band up down 3 Locator battery status 4 Locate Mode 5 Power off 6 Calibration 7 Height Above Ground HAG 8 Settings 9 Transmitter Frequency Optimization FO Toggle to...

Page 2: ...number 4 Maximum noise level 5 Up band 6 Down band 7 Scan rescan 8 Pair 9 Exit Frequency Optimization Results Run the FO for each new project to select an optimal set of frequencies for each band ever...

Page 3: ...oth will pair at the same time and the locator will be set to use the Down band first a Install transmitter Tx batteries and endcap the increase in FO noise readings shows the Tx is on b Select Pair t...

Page 4: ...within 5 Access AGR directly on the Calibration menu Calibrate and check AGR for both new bands If you selected two bands repeat steps 5 6 Calibration and AGR for the second band An error symbol will...

Page 5: ...Tx changes bands data disappears from the locator Below Ground Mid Bore 10 2 7 Roll Method Disable Roll Offset if enabled 1 Roll clock wise to approx 10 o clock 1 CP Wait 10 18 seconds 2 Roll clock wi...

Page 6: ...under the roll clock is full Always take three MAX Mode readings all three must be consistent See the DCI DigiGuide App for important information on this feature Signal Attenuation Signal attenuation...

Page 7: ...at the LL on the line connecting the FLP and the RLP 5 Holding the trigger longer than five seconds enables MAX Mode see page 6 MAX Mode does not have to be at LL or FLP Transmitter Signal Field Geom...

Page 8: ...view 3 Line in the Box at LL 4 HAG on 5 MAX Mode timer 6 MAX Mode icon 7 Tx depth Depth Screen Trigger held at FLP 1 Reference indicator 2 Ball in the Box 3 Roll pitch update meter 4 Tx predicted dept...

Reviews: