background image

page 7

Need information or help?

 Visit www.dccconcepts.com/manuals-advice  OR   email [email protected]

paage 7

7

POWER SWITCH

PRESS to turn ON and OFF

RESET SWITCH.

,WZLOOOLJKWDQGÀDVKLIRYHUORDGSURWHFWLRQLV

activated. (The Alpha-Box unit will beep too)

PRESS and HOLD for 3 seconds to reset

TRACK POWER or SYSTEM BUS Selector Switch

Left position links track power outut from a DCC system, 

5LJKWSRVLWLRQLVXVHGIRU1&(3RZHU&DEFRQQHFWLRQRQ¿UVW

unit or any secondary Alpha-Boxes linked from Alpha-Box #1

6HHVSHFL¿FGLDJUDPVIRUDSSURSULDWHXVHRIWKHVZLWFK

MAIN SYSTEM CONNECTION.

6-Wire RJ12 connector. For connection to 

PowerCab OR secondary connection from 

other brand DCC system (To be used with 

the correct adapter leads only please)

Track power INPUT.
Connect track power from 

ANY DCC system here.

RJ12 DCC system control Bus.

NCE bus can connect directly, all 

other brands require Adapter leads

RJ12 Cobalt

D

Input

Connect Alpha here

Power Input

aY'&

RJ12 CAB bus extension
NCE Cabs connect directly, other 

brands DO require Adapter leads

Track power OUTPUT.

7UDFNa$FFHVVRU\3RZHUEXV

with 5 amp power, protected

RJ12 Control bus link. 
Extend the DCC Control bus or 

link additional Cobalt

D

boxes.

7KH2Qa2II

Switch

The ACC Button

The CAB Button

The RJ12 

Alpha Connection

Alpha

D

Central looks complex, but it is very easy to set up and use. 

Incorporating one Cobalt 

D

Alpha control unit & the contents of two Alpha 

D

Switch-D 

packs, Alpha 

D

Central is the simplest way to create a professional control panel ever!

Page 4 will show you a full set of Alpha 

D

Central features and related information. We 

have included initial connection, set-up and operating procedure here.

CONNECTION: Connect Alpha

D

Central to the ALPHA input of your Alpha 

D

box using the RJ12 curly cord that we supply. (If you are an 

NCE user, you can just connect it directly to the NCE cab bus as both products use standard RS485 bus wiring conventions)
Setting the CAB bus number (Permitted range is 1 ~ 99): Alpha Central needs its own cab number as it is, in effect, the equivalent of 

a DCC handset. You can set it to any cab number within the allowable range for your DC system. Please make sure the number chosen is 

higher than the highest cab number already in use. 

To do this, hold down the CAB button (see Image at right) as you 

turn your Alpha 

D

&HQWUDOXQLWRQ7:2GLJLWVZLOOQRZÀDVK

Use momentary presses of the CAB button to choose which digit 

will be changed. Use momentary presses of the ACC button to 

change the value of the number. When you reach the number 

FKRVHQKROGGRZQWKH&$%EXWWRQXQWLOWKHGLVSOD\ÀDVKHV³<(6´

The cab number is now set. 
Setting multiple Alpha

D

Central unit CAB numbers:

,I\RX¿UVW

link them together, then ALL units will be set simultaneously.
Setting the SWITCH numbers (Permitted range is 1 ~ 2044):
The default is always 1~12, however this can be changed at any 

WLPH6HWWLQJWKH¿UVWVZLWFKQXPEHUZLOOVHW$//RIWKHQXPEHUVLQ

sequence and if multiple Alpha 

D

Central units are connected, then 

ALL switches will be renumbered by setting switch 1 on unit 1.
To do this, hold down the ACC button (see Image at right) as you 

turn your Alpha 

D

&HQWUDOXQLWRQ)285GLJLWVZLOOQRZÀDVK

Use momentary presses of the CAB button to choose which digit 

will be changed. Use momentary presses of the ACC button to 

change the value of the number. When you reach the number 

FKRVHQKROGGRZQWKH&$%EXWWRQXQWLOWKHGLVSOD\ÀDVKHV³<(6´

The Switching addresses of all linked units are now set.

You will need to Connect 

power here if you have 

more than 4 

D

Alpha 

in series. Use a 12v DC 

regulated Power Supply

The Alpha-to-Alpha 

Inter-connection

Summary of Contents for Cobalt alpha

Page 1: ...HOOHUV DQG WKH RYHUDOO OSKD KDV TXLFNO JURZQ WR LQFOXGH D ZLGH JURXS RI SURGXFWV WKDW VLPSOL HV control panel design and creation greatly reduces the complexity of layout wiring and most importantly a...

Page 2: ...switch On input side Cobalt DBox Input Connections are left to right Track power input OK 0 05 to 5 amps track power Main DCC system connection RJ12 type DCCsystem control Cab bus connection RJ12 type...

Page 3: ...k it to an an intelligent Cobalt D box 5A Intelligent power booster andANY modeller DC or DCC can have an active digital accessory power bus up and running in no time at all Each Cobalt DCentral contr...

Page 4: ...ous decoders and other items It just makes good sense to use a top quality properly regulated DC power supply Cobalt D 3RZHU LV D WRS TXDOLW VPRRWKO OWHUHG DQG ZHOO UHJXODWHG DPS RXWSXW SRZHU VXSSO WK...

Page 5: ...a D Switch D Circuit board it is just as easy as assembling LEGO really you cannot get it wrong Step 5 Using DCCconcepts DCD RGB 3 wire ribbon cable connect each output of the Alpha DSwitch D to the i...

Page 6: ...pha D Central to the ALPHA input of your Alpha D box using the RJ12 curly cord that we supply If you are an NCE user you can just connect it directly to the NCE cab bus as both products use standard R...

Page 7: ...al and your control panel will be ready to use the moment you unpack it and connect it to your layout with no added complication at all STEP 2 Connect the Cobalt D Alpha or Cobalt D Alpha Central unit...

Page 8: ...ble supplied with each Alpha Unit Use 1 2 or more Cobalt D Central or Cobalt D Central it s up to you This diagram uses the NCE PowerCab which can connect directly as it uses the conventional RS485 co...

Page 9: ...start set Z21or a Gaugemaster Prodigy Express but now want Accessory control OR if you just want more power from your DCC system and perhaps like the idea of a separated Cobalt DAlpha based Accessory...

Page 10: ...ower districts using Alpha DBox Subject to the use of the correct adapter leads see page 26 27 this will work with ANY DCC SYSTEM ATALL ANY Brand of DCC SYSTEM that has both TRACK POWER and COMMAND BU...

Page 11: ...we can easily add full digital Accessory control by using Cobalt DAlpha or Cobalt DCentral Giving your DCC system much greater abilities Here is how to do it connection by connection PS This is a ZER...

Page 12: ...m with Cobalt D Alpha or Alpha D Central Upgrading Hornby Elite Select E Link Select and E link are often found in Digital Train sets and the Elite has been adopted by many Hornby oriented modellers h...

Page 13: ...o do it connection by connection PS This is a ZERO waste upgrade too because if you change brand later your Cobalt DBox Cobalt DAlpha or Cobalt DCentral will all still work perfectly with it Also conn...

Page 14: ...t soon outgrows the average modellers needs for layout power as its true output power ability is really only 1 5 amps continuous We COULD simply connect the PowerCab panel to the system as per the Pro...

Page 15: ...ry popular however it too can be added to and increased in potential if combined with Cobalt DBox for added power and Cobalt DAlpha or Cobalt DCentral for control panel sophistication As with PowerCab...

Page 16: ...ort of versatility with ALPHA products as NCE as the LENZ bus is actually very similar Therefore subject to the use of the correct LENZ adapter leads you can either use LENZ LA152 adapter plates ORAlp...

Page 17: ...X adapter leads There really is NO limit to the system growth that is possible with Alpha DBox as long as you utilise our DIGITRAX adapter leads too see page 26 27 Connect TRACK power Connect DCC BUS...

Page 18: ...ect bus linking is not possible however Alpha Dbix can still be linked via the 6 wire RJ2 bus for transmission ofAlpha DCentral or Cobalt DAlpha Commands and of course Power District structures adding...

Page 19: ...connect via X bus and so actually have the same sort of versatility with ALPHA products as Lenz as the LENZ ROCO bus are actually very similar Use the correct adapter leads and there really is NO lim...

Page 20: ...d protection This simple diagram shows how to add an accessory power bus or multiple power districts to ROCO using Alpha DBox ROCO users can connect via X bus and so actually have the same sort of ver...

Page 21: ...h these products Please see page 26 27 Using the adapters makes it easy Connect TRACK power Connect DCC BUS Switch TRACK PRODIGY Base Unit ADAPTER P26 27 PRODIGY HANDSET ADAPTER See P26 27 Alpha DPowe...

Page 22: ...e momentary contact sets so you still have 2x free SPDT switches available for your panel LEDs or Interlocking INTERLOCKING LEVER OPERATIONS It is easier than it sounds To interlock two levers just li...

Page 23: ...sers will be delighted to replace their DW FRUG ZLWK WKLV FDEOH DV LW LV 5 PRUH FRQYHQLHQW Please Use ONLY this cord or its equivalent to connect between multiple Cobalt Dbox units Universal RJ 12 Lay...

Page 24: ...able related damage that will NOT be covered by warranty Please note The images used on this page are representative only and the items that you receive may look a little different CobaltDAlpha and Co...

Page 25: ...from track output terminals Bus extensions may need adapters How does it connect If you have a DC or AC powered layout you need NO change to controllers or locos at all but you will need to add a DCC...

Reviews: