14
Trouble Shooting:
In the event of a fault the first thing to try is powering down the machine, turning off the power at the mains and then waiting
ten seconds. You can then power it up again and see if there are any improvements. If not please refer to this troubleshooting
table for causes and solutions.
Fault
Cause
Solution
No power, red power switch is not
illuminated when in on position.
1) Plug fuse blown.
Check plug fuse, if plug type doesn’t
have a fuse contact service.
2) Fault with mains outlet or cord.
Check supply output and check cord for
any damage, breaks or cuts. If cord is
damaged seek replacement.
No display, red power switch
illuminates when in on position.
1) Internal fuse blown.
Check Internal fuse, it is located on the
switch panel next to the red power
switch. Replace if necessary.
Unit not producing warm airflow. Fan
symbol is marked with a X
1) Insufficient airflow
Try positioning the air mover closer to
the Drymatic Boost Bar or use a higher
speed setting. Check that the air mover
meets the minimum requirements.
Unit not producing hot air. No Rotating
graphic is shown in hours display.
1) Machine has not had sufficient time
to heat up.
The machine will check for stable
airflow before gradually ramping up
power. This can take up to five
minutes.
2) Temperature setting is lower than
room ambient.
Increase the temperature setting, it
may be that the room is hotter than
the temperature limit set.
Drymatic Wall and Floor System not
inflating
1) Insufficient airflow
Try positioning the air mover closer to
the Drymatic Boost Bar or use a higher
speed setting. Check that the mat is
well sealed around the Drymatic Boost
Bar and free to inflate. The minimum
recommended airflow of 1100m³/Hr
(650 cfm) is the requirement for the
Drymatic Boost Bar to function
correctly. Inflating mats, depending on
configuration, may require significantly
In the event that this list does not cover your particular issue or the solution does not solve the problem
please contact your local Drymatic representative.