background image

5

E

n

g

lis

h

6

SAFETY INSTRUCTIONS 

CAUTION:

T O   R E D U C E   T H E   R I S K   O F  
E L E C T R I C A L   S H O C K ,   D O   N O T  
REMOVE THE COVER (OR BACK). NO 
USER SERVICEABLE PARTS INSIDE; 
REFER SERVICING TO QUALIFIED 
PERSONNEL.

WARNING

:

TO REDUCE THE RISK OF FIRE OR 

E L E C T R I C A L   S H O C K .   D O   N O T  
EXPOSE THIS APPARATUS TO RAIN 
OR MOISTURE.

This symbol, wherever it appears, alerts you to the presence of uninsulated 
dangerous voltage inside the enclosure - voltage that may be sufficient to constitute 
a risk of shock.

This symbol wherever it appears, alerts you to important operating and 
maintenance instructions in the accompanying literature. Read the   manual.

DETAILED SAFETY INSTRUCTIONS:

Read these instructions

All the safety and operation instructions should be read before the apparatus is operated.

Keep   these instructions

The safety and operating instructions should be retained for future reference.

Heed all warnings

All warnings on the apparatus and in the operating instructions should be adhered to

Follow all instructions:

All operation and user instructions should be followed

Water and moisture

Do not use this apparatus near water (e.g. near a bathtub, washbowl, kitchen sink, laundry tub, in a wet 
basement, or near a swimming pool etc.) except expressly allowed

Cleaning

Clean only with a dry cloth. Do not use solvents, alcohol, benzene or volatile substances for cleaning 
the exterior parts.

Ventilation

Do not block any of the ventilation openings. Install in accordance with the manufacturers instructions. 
The apparatus should be situated so that its location or position does not interfere with its proper 
ventilation. 

Heat

Do not install the apparatus near any heat sources such as radiators, heat registers, stoves, or other 
apparatus (including amplifiers) that produce heat.

Grounding or Polarization

Do not defeat the safety purpose of the polarized or grounding/type plug. To prevent the risk of 
electrical shock, the metallic parts of the speaker must be earthed.   A polarized plug has two blades 
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The 
wide blade or the third prong are provided for your safety. When the provided plug does not fit into your 
outlet, consult an electrician for replacement of the obsolete outlet.
Speaker shall be connected to a MAINS socket outlet with a protective earthing connection.

Power Source

The apparatus should be connected to a power supply only of the type described in the operating 
instructions or as marked on the apparatus. In order not to jeopardize the safety of the speaker, it must 
only be connected to the mains using the power cable provided.
DPDT Mains Switch is used as the disconnect device located at the rear.

Power Cord Protection

Protect the power cord from being walked on or pinched particularly al plugs, convenience receptacles, 
and the point   where they exit from the apparatus.

Accessories

Only use attachments/accessories specified by the manufacturer.

"AVIS"

 

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR 

POUR PREVENIR TOUT RISQUE DE FEU 

REPLACER UN FUSIBLE 

DE MÊME CARACTERISTIQUES

CET APPAREIL DOIT ÊNTRE RELIÉ A LA TERRE

"CAUTION"

 

TO PREVENT ELECTRICAL SHOCK 

DO NOT REMOVE COVER

TO PREVENT RISK OF FIRE 

REPLACE FUSES WITH

SAME TYPE AND RATINGS 

THIS APPARATUS MUST BE EARTHED

Carts and stands 

Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the 
apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid 
injury from tip-over.

Non-use Periods:

Object and Liquid Entry

Damage Requiring Service

Servicing:

IMPORTANT NOTES

This manual is to be considered an integral part of the product, and must always accompany the 
speaker when it changes ownership as a reference for correct installation and operation as well as for 
the safety regulations.

dB Technologies will not assume any responsibility for incorrect installation of the speaker.

OPERATING PRECAUTIONS

-

Do not force the amplifier incorporated in the speaker to work in overload for extended periods 

of time.

-

Never force the control elements (switches, controls, etc.).

CAUTION

-

Make sure that the speaker is positioned in a stable and secure way in order to avoid any 

dangerous conditions for persons or objects.

CONNECTION

-

For connecting the speaker, use only qualified and experienced personnel having sufficient 

technical knowledge or specific instructions for making the connections correctly and thus 
preventing electrical dangers.

-

To prevent the risk of electrical shock, the speaker must only be supplied from the mains after all 

connections have been completed.

-

Before powering up the speaker, it is advisable to re-check all the connections, making sure in 

particular that there are no short circuits.

-

The entire sound system must be designed and installed in compliance with the current 

standards and regulations regarding electrical systems.

CAUTION

-

To prevent inductive phenomena from giving rise to hum or disturbance which would jeopardize 

efficient speaker operation, the cables that transmit microphone signals or line level signals 
(e.g. 0 dB/V) must be screened and should not be run in the vicinity of:
1)

Equipment that produces strong magnetic fields (e.g. large power supply transformers)

2)

Electrical energy conductors

3)

Lines that supply speakers.

PROTECTION SYSTEM

The speaker is equipped of a exclusive system, which protects the loudspeakers against overheating, 
ensuring the maximum reliability in all professional applications. In addition, a sophisticated system 
incorporated in the amplifier handles the limiter circuits and the protection against overheating and 
short circuits.

Unplug this apparatus during lightning storms or   when unused for long periods of time.

Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through 
openings.

Refer all servicing to qualified service personnel. Servicing is required when:
-

the apparatus has been damaged in any way;

the power-supply cord or the plug has been damaged; 

-

the liquid had been spilled or objects have fallen into the apparatus;

the apparatus has been exposed to rain or moisture

the apparatus does not operate normally or exhibits a marked change in performance;

the apparatus had been dropped.

The user should not attempt to service the apparatus beyond that is described in the Operating 
Instructions.   All other servicing should be referred to qualified service personnel.

CAUTION

E

n

g

lis

h

Summary of Contents for Stage Monitor M10-2 PLUS

Page 1: ...ogies aeb com B B d d TECHNOLOGIES TECHNOLOGIES MANUALE D USO USER MANUAL BEDIENUNGSANLEITUNG CARACTERISTIQUES TECHNIQUES PROFESSIONAL ACTIVE SPEAKER PROFESSIONAL ACTIVE SPEAKER Manufactured in India under dB Technologies control Manufactured in India under dB Technologies control COD 420120125 M12 4 PLUS STAGE MONITOR STAGE MONITOR series series M10 2 PLUS ...

Page 2: ...HIO DI SCOSSA E L E T T R I C A N O N T O G L I E R E I L C O P E R C H I O O I L PA N N E L L O POSTERIORE ALL INTERNO NON SONO C O N T E N U T E PA R T I R I PA R A B I L I DALL UTENTE AFFIDARE LE RIPARAZIONI APERSONALE QUALIFICATO ATTENZIONE PER RIDURRE IL RISCHIO DI INCENDIO O DI SCOSSA ELETTRICA NON ESPORRE QUESTO APPARECCHIO ALLA PIOGGIA O ALL UMIDITÀ Questo simbolo dove compare ha lo scopo ...

Page 3: ...ONI Italiano Italiano Italiano Manuale d uso Manuale d uso 4 Italiano Italiano Italiano Manuale d uso Manuale d uso 3 DATI TECNICI M10 2 PLUS M12 4 PLUS Sistema ATTIVO BI AMP ATTIVO BI AMP Tipologia amplificatore ALTI classe AB ALTI classe AB BASSI classe H BASSI classe H Potenza RMS 150W LF 50W HF 250W LF 50W HF Potenza musicale 300W LF 100W HF 500W LF 100W HF Risposta in frequenza 3dB 70 19 000 ...

Page 4: ... A LA TERRE CAUTION TO PREVENT ELECTRICAL SHOCK DO NOT REMOVE COVER TO PREVENT RISK OF FIRE REPLACE FUSES WITH SAME TYPE AND RATINGS THIS APPARATUS MUST BE EARTHED Carts and stands Use only with a cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over Non us...

Page 5: ...to change the coverage angle PIC 2 undo the fixing screws of the grille remove the front protective grille by slightly pressing on one side and taking the grille off the special slots undo the eight fixing screws of the horn rotate the horn in the desired position the horn should never be removed from the loudspeaker tighten the fixing screws of the horn put the grille back in the special side slo...

Page 6: ...CET APPAREIL DOIT ÊNTRE RELIÉ A LA TERRE CAUTION TO PREVENT ELECTRICAL SHOCK DO NOT REMOVE COVER TO PREVENT RISK OF FIRE REPLACE FUSES WITH SAME TYPE AND RATINGS THIS APPARATUS MUST BE EARTHED Bei längerer Nichtverwendung Bei Gewitter oder bei längerer Nichtverwendung das Gerät von der Netzsteckdose trennen Eindringen von Fremdkörpern oder Flüssigkeiten in das Gerät Sicherstellen dass das Gerät vo...

Page 7: ...s Hornes von 90 waagerecht Wenn man den Schallabstrahlungswinkel des Hornes ändern möchte soll man BILD 2 die Befestigungsschrauben des Netzes ausschrauben das vordere Schutznetz entfernen indem man einen leichten Druck auf einer Seite ausübt und indem man es von ihren Vertiefungen aufhebt die acht Befestigungsschrauben des Hornes herausdrehen das Horn in die gewünschte Richtung drehen den Satz de...

Page 8: ...LE DE MÊME CARACTERISTIQUES CET APPAREIL DOIT ÊNTRE RELIÉ A LA TERRE CAUTION TO PREVENT ELECTRICAL SHOCK DO NOT REMOVE COVER TO PREVENT RISK OF FIRE REPLACE FUSES WITH SAME TYPE AND RATINGS THIS APPARATUS MUST BE EARTHED Chariots et support Périodes de non utilisation Entrée de liquides et d objets dans l appareil Veiller à ce qu aucun objet ne tombe sur l appareil et qu aucun liquide ne passe à t...

Page 9: ...abrique toujours avec le cône orienté à 90 dans le sens horizontal Si on veut modifier l angle de couverture du cône il faut nécessairement FIG 2 dévisser les vis de fixation du réseau enlever la protection antérieure en exerçant une légère pression sur un côté et en la soulevant de ses encastrements dévisser les huit vis de fixation du cône faire rouler le cône dans la position désirée ne jamais ...

Page 10: ...10 2 M10 2 dBTECHNOLOGIES TECHNOLOGIES ON OFF POWER EARTH VOLTAGE SELECTOR FUSE MAINS BALANCED INPUTS LINKS BI AMP H CLASS ACTIVE MONITOR PLUS PLUS LIMITER POWER MAX 0 VOLUME VOLUME SERIAL N SERIAL N EQU EQU FLAT MID FREQUENCY EQUALIZER STATUS STATUS INPUT SENSITIVITY 0dBu BALANCED INPUT IMPEDANCE 30KÙ 1 2 3 4 5 6 9 8 7 1 3 2 4 5 7 9 8 6 ANGOLO DI COPERTURA TROMBA HORN ANGLE COVERED HOCHTONHORN AB...

Page 11: ...CER UN FUSIBLE DE MÊME CARACTERISTIQUES CET APPAREIL DOIT ÊNTRE RELIÉ A LA TERRE CAUTION TO PREVENT ELECTRICAL SHOCK DO NOT REMOVE COVER TO PREVENT RISK OF FIRE REPLACE FUSES WITH SAME TYPE AND RATINGS THIS APPARATUS MUST BE EARTHED BI AMP H CLASS ACTIVE MONITOR PLUS PLUS LIMITER POWER MAX 0 VOLUME SERIAL N EQU FLAT MID FREQUENCY EQUALIZER STATUS INPUT SENSITIVITY 0dBu BALANCED INPUT IMPEDANCE 30K...

Page 12: ... oct BALANCED INPUTS LINK L N MAINS FUSE POWER SWITCH VOLTAGE SELECTOR INTERNAL AMPLIFIER TRANSFORMER LIMITER INDICATOR POWER INDICATOR DELAY EQUALIZATION WOOFER 12 12dB oct VOLUME DRIVER 1 M10 2 PLUS 12dB oct 12dB oct BALANCED INPUTS LINK L N MAINS FUSE POWER SWITCH VOLTAGE SELECTOR INTERNAL AMPLIFIER TRANSFORMER LIMITER INDICATOR POWER INDICATOR DELAY EQUALIZATION WOOFER 10 22 M12 4 PLUS M12 4 P...

Page 13: ... Positivo Caldo Fase VE Pin 1 Schermo Terra Massa Pin 1 Schermo Terra Massa Pin 2 Positivo Caldo Fase VE Pin 3 Negativo Freddo Fase VE COLLEGAMENTI CONNECTIONS BRANCHEMENTS ANSCHLÜSSE Tip Sleeve Tip Signal Sleeve Screen Ground Earth Unbalanced use of stereo 1 4 jack plug Tip Ring Sleeve Tip Positive Hot VE Phase Ring Negative Cold VE Phase Sleeve Screen Ground Earth Balanced use of stereo 1 4 jack...

Reviews: