SUB 918                                                                                                                                            420120323Q REV 1.0 

3) First switch on  

The DIGIPRO G3 amplifier of SUB 918 is controlled by a 
powerful DSP. All the connections and controls are in 
the rear amplifier control panel: 
 

 
 
 

1      Input (balanced) connector  
2      Output Xover/Link (balanced) connector 
3      RDNet Data In 
4      RDNet Data Out 
5      RDNet status LEDs 
6      Subwoofer delay [ms] rotary  
7      Xover/Link frequency selector  
8      General Status LEDs 
9      Input sensitivity  
10    Subwoofer polarity 
11    Usb data service 
12    Mains Input (Auto-range) 
13    Mains Link  
14    Mains Fuse 

 
The subwoofer is supplied with one mounted fuse for 
operation within the 220-240V~ range. If you need to 
operate in the 100-120V~ voltage range: 

 

Disconnect  all  connections,  including  the  power 
supply 

 

Wait 5 minutes 

 

Replace the fuses with the ones provided in the 
package for the 100-120V~ range 

 
 
 

a)

 

 Once  you  have  properly  set  up  the  desired 

configuration  (see  also  the  SUB  918  complete  user 
manual  and  accessories  instructions  for  further 
information),  connect  the  audio  input  (

1

).  Set  the 

Subwoofer polarity (

10

) and Input Sensitivity (

9

) to the 

desired level. 
b) Connect  the  possible  Xover/Link  output  (

2

)  and 

adjust the related frequency (

7

). 

c) Adjust the subwoofer delay (

6

)  

d) 

In case of remote control, connect the Data Input (

3

to the hardware remote controller (RDNet Control 2 or 
RDNet Control 8) with cables equipped with etherCON 
connectors.  Then  connect  the  Data  Output  (

4

)  to  the 

Data Input (

3

) of a possible second device, and so on. 

When the RDNet network is on and it has recognized 
the  connected  device,  the  LED  “Link”  (

5

)  is  on.  The 

other LEDs (

5

) “Active” start blinking at the presence of 

data  transmission,  the  “Remote  Preset  Active”  advise 
that  all  the  local  controls  set  on  the  amplifier  panel 
(level, DSP presets, etc.) are by-passed and controlled 
remotely by RDNet.  
In  remote  control  it  is  essential  the  use  of  free 
dBTechnologies software: 

 

dBTechnologies AURORA NET, 

necessary for an in-depth real-time control of different 
devices; 

e) 

Connect the power supply (

12

). It is possible to link 

other  sub  918  using  mains  link  connector  (

13

)  (see 

Technical Data for further information).

 

 

Check the complete user manual on 

www.dbtechnologies.com 

for further 

information about the system and available accessories. 

Scarica  il  manuale  completo  da 

www.dbtechnologies.com

 

per  ogni 

ulteriore informazione sul sistema e sugli accessori disponibili. 

Für  weitere  Informationen  und  verfügbares  Zubehör  lesen  sie  bitte  die 
vollständige Bedienungsanleitung unter

 

www.dbtechnologies.de

.

 

Vérifiez le manuel de l'utilisateur complet sur 

www.dbtechnologies.com

 

pour  des  informations  complémentaires  du  système  et  des  accessoires 
disponibles.

Compruebe 

el 

manual 

de 

usuario 

completo 

sobre 

www.dbtechnologies.com

 para la información adicional sobre el sistema 

y accesorios disponibles.

 

Reviews: